Vacsure - Vacuum Blood Collection Tubes (PET)
CML Biotech - Vacsure Sodium Citrate 3.2% Tubes (PT Tubes)
These tubes contain buffered tri- sodium provided in 3.2%. The mixing ratio is 1 part citrate to 9 parts blood. Gently invert the tube 180° 3-4 times and centrifuge at 2000-3000 rpm for 10 min.. Used for coagulation tests like PT, PTT, TT, Fibrinogen and FDP, D-dimer and many special coagulation tests to diagnosis various bleeding disorders such as Factor activity assays.
Vacsure Clot Accelerator + Gel Tube
These tubes contain spray coated silicon and micronized silica particles to accelerate clotting .It also contains an inert separator Gel on the base of the tube for serum separation .Gently invert the tube 180° 8-10 times and after coagulation, centrifuge at 2000-3000 rpm for 10 min. at room temperature. The specific gravity make the barrier gel move upward to the serum- clot interface during centrifugation and it forms a stable barrier separating serum from fibrin cells. This barrier provides stability of certain parameters of the tubes under the recommended conditions for up to 48 hours. Used for serum determinations in Bio-Chemistry, Immunology and serology. Antibody screening, Indirect Anti globulin Test, Cross match, Antigen Typing, IM, and Drug assays etc.
Safelab - Non Vacuum Blood Collection Tubes (Double Cap)
Safelab - Clot Accelerator Tubes
Usage :-These tubes are used for Biochemistry, Immunology and Serology tests.Gently invert the tube1800 8-10 times . The Sample will completely clot in 4-7 minutes.
Safelab - Non Vacuum Blood Collection Tubes (Double Cap)
Usage :-Used mainly in Hematology and testing whole blood in molecular diagnosis. EDTA tubes are used for direct sample analysis since erythrocytes, leucocytes and thrombocytes are stable in EDTA anti coagulated blood for 24 hours. Should gently invert 1800 8-10 times or roll in blood roller mixer to assure complete mixing with blood.
Vacsure - Multi Sample Needle
Vacsure - Multi Sample Sterile Single Use Needle
Vacsure multi sample sterile single use needle consist of double pointed sharp and smooth edges needle makes patient painless. Short end covers with the thin latex free, non toxic rubber sheath which allows blood flow into the collection tube and stops blood flow once the desired exact volume is filled in the tube. Easy to change the tubes without taking out the needle.
Vacsure - Vacuum Blood Collection Tubes (PET)
Vacsure - Plain Tube Without Additives
Used mainly for Biochemistry, immunology and serology tests. After coagulation, Centrifuge at 2000-3000 rpm for 10 min.at room temperature.
Vacsure - Clot Accelerator Tubes
Clot Accelerator tubes contain spray coated silicon and micronized silica particles to accelerate clotting within 5-7 minutes. Gently invert the tube180° 8-10 times. After coagulation, Centrifuge at 2000-3000 rpm for 10 min. at room temperature. Mainly used for Biochemistry, Immunology and serology tests. ABO typing, Antibody screening, Antigen typing, RF, IM, RPR, ASO, CRP, HIV, HBsAg, HCV etc.
Vacsure - Lithium Heparin Tubes
These tubes are spray coated with Lithium Heparin. Heparin activates anti thrombins, thus blocking the coagulation cascade, produce a plasma sample. Gently invert the tubes 180° 5-8 times immediately after blood collection or mix in roller mixer. Centrifuge at 2000-3000 rpm for 10 min. at room temperature. Used for emergency Biochemistry test, Endocrine and metabolic disorders, Therapeutic Drug monitoring and Toxicology, Electrolytes, Clinical chemistry, Serology and immunology etc. Lithium test should not be performed using Lithium Heparin tubes.
Vacsure - Sodium Heparin Tubes
Sodium Heparin is coated to inhibit clotting. Heparin activates anti thrombins, thus blocking the coagulation cascade, produce a plasma sample. Gently invert the tubes 180° 5-8 times immediately after blood collection or mix using roller mixer. Used for emergency Biochemistry test, but also for Endocrine and metabolic disorders, Therapeutic Drug monitoring and Toxicology, Electrolytes, Clinical chemistry, Serology and immunology etc. Centrifuge at 2000-3000 rpm for 10 min. at room temperature.
Instruments
Blood Roller Mixer
This instrument is used for complete mixing of blood in blood collection tubes. It can roll and swing blood collection tubes in its 5 rollers . Rotation speed can be adjusted and accommodate 6-8 nos or13x75mm/13x100mm or 8 nos vials.