endocon GmbH
8 products found

endocon GmbH products

UltraPower - Surgical Drill System

The Hall`s UltraPower System is designed for use in revision operations, spinal cord, neurological, and small bone operations. Bone, but also monoblock and other implants, can be dissected or separated intraoperatively using various drilling and milling attachments. Non-releasable metal compounds can also be easily separated. Broken implants are drilled and processed to make them easier to remove. The pneumatic system provides exceptional performance and is indispensable for complex revision operations.

Torsional Orthopaedic Revision System

The TORS system is currently the world`s newest and most modern surgical ultrasound device for the removal of polymethyl methacrylate (PMMA) bone cement. The system also contains an HF surgery module / device for high-frequency, tissue cutting and coagulation of vessels. The technically mature system impresses with its extremely stable functional performance compared to the systems available on the market, as well as simple and pleasant handling.

Hip Stem Extraction Tool

The EndoDriver is a proven surgical instrument for total hip replacement femoral components that should be available in every revision surgery. Revision operations are safer and better when scheduled with this instrument. Only a few steps necessary for safe fixation of the instrument to the neck of the prosthesis, Axial force transfer and stable clamping force by patented system, Transfer of clamping force along a curved tool head to the prosthesis cone, Minimized size of the instrument head, designed for limited space conditions, Efficient, rational and cost-saving surgical operations, Since 1993 successfull in clinical use, Complete decomposability of the instrument without additional tools, Easy and validated instrument reprocessing,

safeConnect - Safe Impaction of Taper Junctions

The result of applying manual forces with a mallet to join taper junctions of femoral heads and cup inlays is a wide range of impaction forces. This represents a potential risk for corrosion and micro motion at the taper junction. Current scientific studies show that a high and constant impact force has a significant impact on the joined tapers’ safety. Under continuous scientific evaluation a standardized impacting procedure has been developed which guarantees a replicable force application to the taper junctions of femoral heads and cup inlays. A new instrument replaces the mallet driven and manual impaction process. safeConnect is therefore the essential instrument for primary and revision arthroplasty.

Acetabular Cup Extractor

Quickly and precisely remove cemented and cementless acetabular endoprostheses of all sizes. Universally applicable for all sizes thanks to continuously variable tensioning of the instrument.