LuxarCare LLC products
Medical Laser Accessories
LightScalpel - Model LS 9000 Series - Flexible Waveguides
The new and improved LightScalpel Flexible Waveguides are the most versatile and cost-effective waveguide solutions for owners of Luxar and Lumenis laser systems.
LuxarCare - Straight Handpieces
These general-purpose straight rotational handpieces are the most versatile and cost-effective handpiece solutions for owners of Luxar, and Lumenis CO2 flexible-waveguide laser systems.
Veterinary Laser Accessories
LuxarCare - Model VF-1.5 - Aesculight Flexible Fiber
Available only from Aesculight and Luxarcare, this patented fiber is rugged and yet very flexible, providing the surgeon with a scalpel-like feel, enhanced beam pointing accuracy, and precise access to the most difficult operating fields. 1.5 meter length.
LuxarCare - Aesculight Adjustable Tipless Handpiece
The adjustable tipless handpiece eliminates the need for laser tips, and allows the surgeon to effortlessly alternate between any one of four spot sizes intra-operatively while maintaining a sterile field. Laser focal spot diameters: 0.25, 0.4, 0.8, 1.4 mm.
Upgrade to Aesculight
Aesculight - Veterinary Surgical CO2 Lasers System
Unlike any other veterinary CO2 lasers manufactured overseas, every Aesculight veterinary laser is assembled in the USA and can be maintained for you for many years by the same laser engineers who designed and hand-built it here in the USA.
Upgrade to LightScalpel
LightScalpel - Surgical CO2 Lasers System
Unlike any other surgical or dental CO2 lasers manufactured overseas, all LightScalpel lasers are assembled in the USA and reliably maintained for you by the same laser engineers who designed and built them right here in America.
Luxar Laser Systems
Luxar - Model LX-20SP - Surgical CO2 Laser System
Laser wavelength (micrometers): 10.6; CW power to tissue (watts): 2 - 20; Average SP power to tissue (watts): 2 - 10; Laser tube peak SP power (watts): 50; Single pulse exposure times (msec): 5, 10, 15, 20, 25, 50, 100, 200, 500; Single pulse energy (mJoules): 10 - 10,000; Popular laser tip spot diameters to tissue (mm): 0.25, 0.4, 0.8; Max laser tip spot power density (w/cm2): 40,000; Number of pre-programmed repeat pulse modes: 102; Your source for fiber waveguides, handpieces, and laser tips: Luxarcare; Your source for free over-the-phone technical support: Luxarcare; Your source for service and maintenance: Luxarcare; Many obsolete parts: Call Us; Laser tube life expectancy before gas needs recharge (not replacement): 5 - 7 years; Laser fiber life expectancy (dependent on usage): 1 - 4 years.
Luxar - Model LX-20SI - Surgical CO2 Laser System
Laser wavelength (micrometers): 10.6; CW power to tissue (watts): 2 - 20; Average SP power to tissue (watts): Laser tube peak SP power (watts); Single pulse exposure times (msec): 5, 10, 15, 20, 25, 50, 100, 200, 500; Single pulse energy (mJoules): 10 - 10,000; Popular laser tip spot diameters to tissue (mm): 0.25, 0.4, 0.8; Max laser tip spot power density (w/cm2): 40,000; Number of pre-programmed repeat pulse modes: 10; Your source for fiber waveguides, handpieces, and laser tips: Luxarcare; Your source for free over-the-phone technical support: Luxarcare; Your source for service and maintenance: Luxarcare; Many obsolete parts: Call Us; Laser tube life expectancy before gas needs recharge (not replacement): 5 - 7 years; Laser fiber life expectancy (dependent on usage): 1 - 4 years.
Luxar - Model LX-20 / LX-20i - Surgical CO2 Laser System
Laser wavelength (micrometers): 10.6; CW power to tissue (watts): 2 - 20; Average SP power to tissue (watts): Laser tube peak SP power (watts); Single pulse exposure times (msec): 5, 10, 20, 50, 100, 200; Single pulse energy (mJoules): 10 - 4,000; Popular laser tip spot diameters to tissue (mm): 0.25, 0.4, 0.8; Max laser tip spot power density (w/cm2): 40,000; Number of pre-programmed repeat pulse modes: 10; Your source for fiber waveguides, handpieces, and laser tips: Luxarcare; Your source for free over-the-phone technical support: Luxarcare; Your source for service and maintenance: Luxarcare; Many obsolete parts: Call Us; Laser tube life expectancy before gas needs recharge (not replacement): 5 - 7 years; Laser fiber life expectancy (dependent on usage): 1 - 4 years.
Luxar - Model LX-20LP - Surgical CO2 Laser System
Laser wavelength (micrometers): 10.6; CW power to tissue (watts): 2 - 12; Average SP power to tissue (watts); Laser tube peak SP power (watts); Single pulse exposure times (msec): 5, 10, 15, 20; Single pulse energy (mJoules): 10 - 240; Popular laser tip spot diameters to tissue (mm): 0.25, 0.4, 0.8; Max laser tip spot power density (w/cm2): 24,000; Number of pre-programmed repeat pulse modes: 3; Your source for fiber waveguides, handpieces, and laser tips: Luxarcare; Your source for free over-the-phone technical support: Luxarcare; Your source for service and maintenance: Luxarcare; Many obsolete parts: Call Us; Laser tube life expectancy before gas needs recharge (not replacement): 5 - 7 years; Laser fiber life expectancy (dependent on usage): 1 - 4 years.