Rayner Intraocular Lenses Limited products
IOLs - Monofocal
RayOne - Model EMV - Fully Preloaded Non-Diffractive IOL
RayOne EMV, a new fully preloaded non-diffractive IOL, was designed in collaboration with world renowned surgeon, Professor Graham Barrett. RayOne EMV offers reduced dysphotopsia compared to diffractive IOL designs. This is achieved through a unique aspheric anterior surface which adds to the positive spherical aberration (SA) of the cornea in a controlled manner. This positive SA smoothly transitions to negative SA at the periphery to prevent reducing image quality from positive SA at larger pupil sizes.
RayOne - Model RAO600C - Aspheric Lens
Fully preloaded with Rayner’s clinically superior 600C aspheric lens, RayOne is the world’s smallest incision fully preloaded injector. RayOne Aspheric (RAO600C) offers surgeons a 2.2 mm incision and two-step preparation system to deliver a monofocal with less PCO, less decentration, and a higher Abbe value to ensure reliably superior patient outcomes time after time. RAO600C is available in a wide power range (+8.0 D to +34.0 D) and is completely glistening free.
RayOne - Model RAO100C - Spheric Lens
Fully preloaded with Rayner’s clinically superior 100C spheric lens, RayOne is the world’s smallest incision fully preloaded injector. RayOne Spheric (RAO100C) offers surgeons a sub 2.2 mm incision and two-step preparation system to deliver a monofocal with less PCO, less decentration, and a higher Abbe value to ensure reliably superior patient outcomes time after time. RAO100C is available in a wide power range (+8.0 D to +34.0 D) and is completely glistening free.
RayOne - Model 600C - Aspheric Lens
Built on the clinically-proven Rayner primary IOL platform, the 600C Aspheric is a hydrophilic acrylic aspheric monofocal IOL with our Amon-Apple 360° enhanced square edge. Now FDA Approved in the USA, Rayner’s global lens design offers surgeons a sub-2.2 mm incision IOL for minimal wound damage and surgically-induced astigmatism (SIA). We believe that every patient’s vision is important and there is no such thing as the ‘average’ cornea. That is why the Rayner 600C Aspheric lens is aberration neutral, allowing patients to benefit from the natural residual positive aberration of the cornea. 600C Aspheric is available across a wide power range (+8.0 D to +34.0 D).
RayOne - Model RAO210T - EMV Toric - Fully Preloaded IOL Injection System
High quality natural vision. Developed in collaboration with world renowned surgeon, Professor Graham Barrett, RayOne EMV Toric is a highly versatile lens that meets the visual needs of a large population of cataract and refractive patients3 looking for greater spectacle independence than offered by standard monofocal lenses.
Delivery Systems
RaySert PLUS - Single-Use Injector
RaySert PLUS is a Rayner designed and manufactured single-use injector, for implantation of the C-flex Aspheric IOLs through a 2.2 mm wound assisted clear cornea incision.
IOLS - Toric
Model IOL710T - Sulcoflex Toric - Aspheric Pseudophakic Supplementary IOLs
Rayner Sulcoflex: An elegant solution for treating refractive surprise. Rayner Sulcoflex Aspheric Pseudophakic Supplementary IOLs are designed to be implanted in the ciliary sulcus to correct residual post-operative refractive errors following the implantation of a conventional IOL in the capsular bag.
OVDS
Ophteis - Model FR Pro - Unique Bio-Engineered Visco-Surgical Device
We’ve put a lot of fresh thinking into our new Ophteis FR Pro. It’s a unique bio-engineered Visco-Surgical Device (OVD) containing free radical scavenging sorbitol – designed to deliver a new level of corneal endothelial protection from phaco induced trauma. Containing sorbitol for unparalleled free radical scavenging. Sorbitol acts as an outstanding free radical scavenger, neutralising reactive oxygen species during surgery that causes damage to the endothelium. In fact, when compared to market leading OVDs, studies show that the use of Rayner’s Ophteis FR Pro reduces cell death by an average of 28.4%*. *University of Brighton, UK, in vitro chemical and phaco free radical studies, data to be published.
Rayner - Model Ophteis, Ophteis+ and OphteisMAX - Ophthalmic Viscosurgical Devices
With Ophteis, Ophteis+ and OphteisMAX, Rayner offers a complete range of ophthalmic viscosurgical devices (OVD) made from hyaluronic acid of animal origin. The specific combination of different concentrations of HA and a high molecular weight has led to three distinct products with exemplary and complementary pseudoplastic qualities. The range manufactured in Sweden offers an optically clear OVD with no bubbles and can be stored at room temperature.
Eye Care
Rayner - Model Dropodex - Dexamethasone Phosphate 0.1% w/v Eye Drops
Dropodex Dexamethasone Phosphate 0.1% w/v Eye Drops, Solution. Dropodex is a preservative-free corticosteroid eye drop. Dropodex is classified as a prescription-only medicine (POM) in the UK and is only available in the GB market.
