Ohio Medical Corporation
Retrofit Wall Outlet Brochure
product specificationsF E AT U R E S A N D B E N E F I T S• Accepts Ohmeda® Diamond or DISS Gas Specific Adapters. • Pin indexed to prevent interchangeability of gas services. • Each outlet is cleaned for medical gas service and pressure tested. • Less than 3 psi (21 kPa) pressure drop through the outlet @ 120 l/min and 50 psig (345 kPa) inlet pressure. R e t r o F i t Wa l l O u t l e tQ u i c k C o n n e c t D i a m o n d 2 & 3 t o O h m e d a D i a m o n d o r D I S S C o m p a t i b l eS P E C I F I C AT I O N SThe medical gas retrofit wall outlet shall be Ohio Medical Healthcair® Series, Ohmeda® Diamond or DISS compatible. The latch-valves shall be NFPA compliant, cleaned for medical gas service and be pressure tested. Each latch-valve shall have less than 3 psi(21kPa) pressure drop through the outlet @ 120 l/min. and 50 psig (345 kPa) inlet pressure. For outlets providing positive pressuregas, the outlet shall be equipped with a primary and secondary check valve, allowing the primary check valve to be removed for serv-ice without isolating the entire zone. Latch-valves shall be gas specific by means of a gas specific indexing pin arrangement. The indexing pin shall be arranged in sucha way as to connect the latch-valve assembly only with the specific matching gas back body, preventing interchangeability of gas serv-ices. The latch-valve assembly, which by means of color coding and wording, shall identify the specific medical gas service provided by theoutlet and shall accept only Ohmeda® Diamond or DISS type gas specific adapters. For aesthetic appeal each outlet shall include a one piece chrome trim plate. Equipment is manufactured in the USA and produced in an ISO 13485 registered facility. Ohmeda® is a registered trademark of Ohmeda MedicalOhio Medical Corporation - 1111 Lakeside Drive - Gurnee, IL 60031-4099 USATollFree: 800-448-0770 - Phone: 847-855-0500 - Fax: 847-855-6300www.ohiomedical.comForm No. 255408 (Rev.1) 02/2008product specificationsTRUSTED BRANDS OF OHIO MEDICALRETROFIT KIT FOR DIAMOND 2/3 ROUGH-IN PART NUMBERS261220 Rough-In RetroFit Kit Pressure Gas 261221 Vacuum Rough-In RetroFit KitRETROFIT KIT FOR DIAMOND 2/3 LATCH VALVE PART NUMBERS261170-1 Latch Valve Ohmeda® Oxy 261160-1 Latch Valve DISS Oxy261170-2 Latch Valve Ohmeda® Vac 261160-2 Latch Valve DISS Vac261170-3 Latch Valve Ohmeda® N2O 261160-3 Latch Valve DISS N2O261170-4 Latch Valve Ohmeda® Air 261160-4 Latch valve DISS Air261170-6 Latch Valve Ohmeda® WAGD 261160-5 Latch Valve DISS N2261160-6 Latch Valve DISS WAGD261160-7 Latch Valve DISS CO2
Most popular related searches
