Diagnosys LLC
  1. Companies
  2. Diagnosys LLC
  3. Products
  4. COLORDOME - Advanced Performance ...

COLORDOMEAdvanced Performance Ganzfeld Dome Stimulators

SHARE

Advanced flash capabilities: ColorDome™ has a trillion-to-1 luminance range; Flash duration from nanoseconds to hours; Any color background from RGB and amber LEDs; Easy to use, ultimate performance: Self-calibrating; Full electronic color control; Flash or flicker stimuli in any color & duration; Desktop, cart and floorstand mounts.

Most popular related searches
  • Disease diagnostics and monitoring
  • Research and development
  • Stem cell and genetic research
  • Drug discovery and screening
  • Clinical trials
  • Neuro-ophthalmology

LED flash

  • Any color flash: from RGB & amber LEDs; UV LED also available
  • Red (627 nm), Amber (590 nm), Green (530 nm), Blue (448 nm)
  • LED sets produce 9 order-of-magnitude luminance range
  • Flash duration from nanoseconds to hours
  • Proprietary CIE compensation yields ultra-stable luminance & color output
  • Maximum white flash >60 cd·s/m2 (20x ISCEV standard flash)
  • On/off flashes of any duration, waveforms including sine & exponential, arbitrary wavetable
  • Calibrated in photopic and scotopic units as well as Trolands
  • User defined color and luminance stimuli
  • Auto calibration

Xenon flash

  • Xenon flash calibrated from 0.001 cd·s/m2 to 5,000 cd·s/m2
  • Triple tube for widest range and linearity
  • Auto calibration monitors each flash & adjusts flash duration in real-time
  • Integral filter holder for adding customer filters if required
  • Max white flash >5,000 cd·s/m2 (1,600x ISCEV standard flash)
  • Calibrated in photopic and scotopic units as well as Trolands
  • Capable of double flashes including “double bright flash” protocol

Overall flash

  • Flash luminance range from 10-9 to 5,000 cd·s/m2
  • Anywhere within this >trillion-to-one range, luminance can be changed with no less than 1% resolution

Background illumination

  • Any color background (from RGB and amber LEDs)
  • 6 order-of-magnitude luminance range
  • Calibrated luminance output in cd/m2
  • Calibrated in photopic and scotopic units
  • Colors can be created using CIE coordinates or color picker

EOG test

  • 9 red EOG LEDs spanning 60° as well as the standard 30°
  • Adjustable intensity and cycle time
  • Can be cycled in square wave mode or sinusoidal mode
  • Configurable to have audible beep at the start of every cycle and sweep
  • Backgrounds up to 500 cd/m2 white for non-dilated pupils

Other features

  • Infrared camera with IR LEDs built in; USB interface & video monitor output
  • Built in progressive audible buzzer to warn patients to get ready for next flash
  • User programmable arbitrary LED waveforms with 1ms resolution give full control of luminance and color
  • Optional dark adaptometry and scotopic threshold modules
  • Auto calibration of LED and xenon output

Physical characteristics
Dimensions (HxWxD) 10.2 x 14.2 x 12.2 inches (260 x 360 x 310 mm)
Weight 10 lbs (4.5kg) without stand

  • ALL ISCEV full-field tests
  • C-wave
  • Dark-adapted 30.0 ERG
  • Dark-adapted long wavelength
  • Direct current ERG
  • Double flash ERG
  • Early receptor potential
  • Electro-oculography (EOG)
  • Flash VEP
  • Light-adapted luminanceresponse series
  • Photopic On-Off
  • Photopic negative response
  • Saturated a-wave series
  • Scotopic threshold response
  • S-cone ERG
  • Dark adapted Red Flash

With upgrade modules:

  • Pupillometry
  • Dark Adaptometry
  • DiagnosysFST