Komax - Model VS100 -Vision Test System
The vision system VS100 has a drawer for placing one large to extra large test items. Correct assembly is checked using the camera and the line laser. The Vision System VS100 from Komax Testing offers highly advanced, precise and high-speed component verification. Its camera provides detailed images for easy and efficient evaluation using the Vision Studio nx test software. The VS100 can test for the correct installation of components, the correct insertion depth of components, and carries out surface inspection tests. Configurable interfaces make the VS100 customizable and suitable for integration into automated production lines, allowing for efficient testing. Despite its advanced features, it is easy to use, with standardized interfaces and individual test sequences. Overall, the Vision System VS100 is an ideal solution for a variety of industries, including automotive, electronics, and medical equipment manufacturing.
VS100 Vision Test
Metric
- Dimensions/height min.: 1630 mm
- Dimensions/height max.: 1950 mm
- Dimensions/width min.: 900 mm
- Dimensions/width max.: 1120 mm
- Depth max.: 895 mm
- Total weight, without test adapter (modules) approx.: 350 kg
- Voltage (AC), input min.: 100 V
- Voltage (AC), input max.: 240 V
- Frequency, input min.: 50 Hz
- Frequency, input max.: 60 Hz
- Voltage, input, connector: Safety plug (240 V, 16 A, 3-pin)
- power supply 1, voltage (DC): 24 V
- power supply 1, current (DC) max.: 3 A
- Total power, standard (depending on the number of power supply units) max.: 1000 W
- Ambient temperature, operation min.: 10 °C
- Ambient temperature, operation max.: 40 °C
- Ambient temperature, storage min.: -10 °C
- Ambient temperature, storage max.: 60 °C
- Air humidity non-condensing min.: 30 %
- Air humidity non-condensing max.: 75 %
- Emission sound pressure level (according to DIN 45635) max.: 80 dB
- Protection class: IP 10
- Test grid width: 400 mm
- Test grid depth, horizontal: 400 mm
- Test grid area: 0.16 m²
- max. number of test adapters (modules) to be installed for size100x100: 1
- Test grid inclination, horizontal: 0 °
- Maximum permissible load on the test grid: 1,1 / 100 g/cm²
- Operating pressure (according to ISO 8573-1: 5/5/4) min.: 5 bar
- Operating pressure (according to ISO 8573-1: 5/5/4) max.: 7 bar
- Compressed-air connection: Kupplungsstecker Rectus G1/4 26AF AW13
- Pneumatic connections min.: 1
- Pneumatic connections max.: 10
- Operating system Windows, based: ja
- Test software CS WIN nx ®, compatible with all systems: ja
- Height control (line laser): Dimensions of test area, length min.: 10 mm
- Height control (line laser): Dimensions of test area, length (depending of the axis) max.: 300 mm
- Height control (line laser): Dimensions of test area, width min.: 5 mm
- Height control (line laser): Dimensions of test area, width max.: 200 mm
- Height control (line laser): Linear unit, axis speed min.: 30 mm/s
- Height control (line laser): Linear unit, axis speed max.: 200 mm/s
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) min.: 1500 ms
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) max.: 3500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) min.: 1500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) max.: 3500 ms
- Vision test (Camera): Dimensions of the test area, length: 300 mm
- Vision test (Camera): Dimensions of the test area, width: 200 mm
- Vision test (Camera): Exposure time: 125 ms
- Vision test (Camera): Possible camera resolution: 2.3, 5.0, 6.2 Mpixel
- Vision test (Camera): Total test time depending on Number of different types (e.g. approx. 8): 50 ms
- Vision test (Camera): Total test time depending on Number of models learned (e.g. approx. 3 per type): 50 ms
- Vision test (Camera): Total test time depending on Number of test positions (e.g. approx. 50): 50 ms
- Vision test (camera): Total test time max.: 300 ms
Imperial
- Dimensions/height min.: 64.17 in
- Dimensions/height max.: 76.77 in
- Dimensions/width min.: 35.43 in
- Dimensions/width max.: 44.09 in
- Depth max.: 35.25 in
- Total weight, without test adapter (modules) approx.: 771.61 lb
- Voltage (AC), input min.: 100 V
- Voltage (AC), input max.: 240 V
- Frequency, input min.: 50 Hz
- Frequency, input max.: 60 Hz
- Voltage, input, connector: Safety plug (240 V, 16 A, 3-pin)
- power supply 1, voltage (DC): 24 V
- power supply 1, current (DC) max.: 3 A
- Total power, standard (depending on the number of power supply units) max.: 1000 W
- Ambient temperature, operation min.: 50 °F
- Ambient temperature, operation max.: 104 °F
- Ambient temperature, storage min.: 14 °F
- Ambient temperature, storage max.: 140 °F
- Air humidity non-condensing min.: 30 %
- Air humidity non-condensing max.: 75 %
- Emission sound pressure level (according to DIN 45635) max.: 80 dB
- Protection class: IP 10
- Test grid width: 15.74 in
- Test grid depth, horizontal: 15.74 in
- Test grid area: 1.72 ft²
- max. number of test adapters (modules) to be installed for size100x100: 1
- Test grid inclination, horizontal: 0 °
- Maximum permissible load on the test grid: 2,42 / 15,5 lb/in²
- Operating pressure (according to ISO 8573-1: 5/5/4) min.: 72.51 psi
- Operating pressure (according to ISO 8573-1: 5/5/4) max.: 101.52 psi
- Pneumatic connections min.: 1
- Pneumatic connections max.: 10
- Operating system Windows, based: ja
- Test software CS WIN nx ®, compatible with all systems: ja
- Height control (line laser): Dimensions of test area, length min.: 0.39 in
- Height control (line laser): Dimensions of test area, length (depending of the axis) max.: 11.81 in
- Height control (line laser): Dimensions of test area, width min.: 0.19 in
- Height control (line laser): Dimensions of test area, width max.: 7.87 in
- Height control (line laser): Linear unit, axis speed min.: 1.18 in/s
- Height control (line laser): Linear unit, axis speed max.: 7.87 in/s
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) min.: 1500 ms
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) max.: 3500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) min.: 1500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) max.: 3500 ms
- Vision test (Camera): Dimensions of the test area, length: 11.81 in
- Vision test (Camera): Dimensions of the test area, width: 7.87 in
- Vision test (Camera): Exposure time: 125 ms
- Vision test (Camera): Possible camera resolution: 2.3, 5.0, 6.2 Mpixel
- Vision test (Camera): Total test time depending on Number of different types (e.g. approx. 8): 50 ms
- Vision test (Camera): Total test time depending on Number of models learned (e.g. approx. 3 per type): 50 ms
- Vision test (Camera): Total test time depending on Number of test positions (e.g. approx. 50): 50 ms
- Vision test (camera): Total test time max.: 300 ms