Max More SpinePercutaneous Transforaminal Endoscopic Discectomy (PTED) Endoscopic System

SHARE

Neurological safety during transforaminal endoscopic surgery of the spine is of paramount importance. In order not to irritate neurological structures close to the foramen and to ensure safe access to the spinal canal, the caudal part of the foramen is widened incrementally with specially designed, patented manual bone drills.

Most popular related searches

Herniations: Lumbar, thoracic.

  • Stenosis: Extraforaminal, foraminal & Lateral Recess
  • Techniques: Outside-in, Inside-out & Outside-out technique

To approach the spinal canal & disc through the foramen a posterolateral approach to the intervertebral foramen is used. The needle is guided to the superior articular process / lateral facet and infiltrated with local anaesthetic. A guide wire is inserted through the needle and the needle removed. Soft tissue is dilatation is performed with serial dilators. The Tom Shidi Needle (Bone needle) is introduced over the guide wire & docked on the superior articular facet ventrally and gently tapped with mallet till it reaches in line with the medial border of the pedicle to the desired location targeting the herniation. The SAP is sequentially drilled with the patented manual bone drills till the desired size is achieved & foramen enlarged. A conical dilator is tapped to the desired location and working sleeve introduced over the dilator.

The Endoscope is introduced through the working sleeve. With resection instruments, the herniated disc material is removed under direct vision. Confirmation of decompression & free neurological structures are confirmed under direct vision.

1001 – SK 1 transforaminal starter kit incl. 1 endoscope 3.7 mm or 4.1 mm working channel
  • 3.7 MM OR 4.1 MM WORKING CHANNEL
  • 193 MM WORKING LENGTH
  • RED 30° ANGLED DIRECTION OF VIEW
  • SUCTION AND IRRIGATION CHANNEL WITH LUERLOCK
  • FIRST CLASS COMPACT OBJECTIVES
  • LATEST GENERATION OF ROD LENSES GUARANTEES AN ILLUMINATION WHICH REALLY IS SECOND TO NONE
  • SCRATCH-PROOF SAPHIRE GLASS ON THE DISTAL END AND ON THE OCULAR SIDE
  • GOLD SOLDERED AT PROXIMAL AND DISTAL END. 100% LEAKPROOF AND MORE RESISTANT
  • BRILLIANT ILLUMINATION AND CRYSTAL CLEAR RESOLUTION
  • TRUE COLOUR REFLECTION AND REGULAR FOCUS ON THE WHOLE IMAGE
  • OPTIMAL DEPTH OF FIELD
  • STORZ – OLYMPUS – TEKNO / WOLF / ACMI ADAPTERS INCLUDED
  • AUTOCLAVABLE
  • INCL. 5 SEALING CAPS AND 2 CLEANING BRUSHES
  • MADE IN GERMANY
  • CE, FDA