Marker Delivery System Articles & Analysis: Older
2 articles found
Presented patient had a tight Medina 1.1.1 RPL/PDA bifurcation lesion. Femoral access was obtained. Predilatation was performed with a 2.0/16mm NC balloon. A 2.5/3.0mm Tryton Side Branch Stent was chosen. Optimal positioning using the 4 radiopaque markers on the delivery system. After Tryton deployment in the PDA, the POT was performed with a semi-compliant 3.0/10mm balloon. A 3.0/18mm DES was ...
This large LAD/D1 Medina 1.1.1 bifurcation lesion with complex anatomy needed a different treatment strategy than the provisional method to ensure the D1 remained protected when treating the LAD lesion. Aggressive predilatation of the D1 was performed with a 2.5/12mm NC balloon. A Tryton 2.5/3.0mm was positioned using the two middle markers of the delivery system. POT was performed with a ...