Genesee BioMedical, Inc. products
Heart Valve Repair
Genesee TruForm - Sievers Annuloplasty Ring
True Physiological Repair: The TruForm Sievers Annuloplasty Ring is designed to maintain optimum conditions throughout the cardiac cycle, allowing the valve to remain in a mechanically reduced state of stress. Implantation is facilitated as the ring is congruent to surgical landmarks; the ring fits to the surgically relevant structures. The TruForm Sievers Annuloplasty Ring addresses the shape of the mitral annulus and adjacent structures including the trigones, left ventricular outflow tract and the aortic annulus.
Genesee FlexForm - Annuloplasty Rings and Bands
Design Advantage: Unique braided material provides easy needle penetration and reduces risk of bunching or crimping. Five markers are provided as landmarks for suture placement.
NeoForm - Annuloplasty Ring
Geometrically designed to restore leaflet coaptation and reduce mitral regurgitation (caused by the enlargement of the left ventricle).
Retractors for Cardiac Surgery
Genesee - Model BMI 35 - Large Adult Retractor
Optimal Exposure For Large Patients with High BMI’s. Large Adult Sternal Retractor with Interchangeable Valve Accessories. Innovative Design: Unique rack design opens with a gently curved radius, optimizing exposure with minimal trauma to the chest and ribcage. Anatomic curved shape distributes opening pressure equally on the sternum. Extra deep blades provide maximum exposure for patients with a BMI of 35 and above. Suitable for adult patients above 90 kilos.
Genesee - Adult Curved Sternal Retractor
Multipurpose Retractor for valve repair, valve replacement and on or off-pump coronary artery procedures. Innovative Design: Unique rack design opens with a gently curved radius, optimizing exposure with minimal trauma to the chest and ribcage. Anatomic curved shape distributes opening pressure equally on the sternum. Pivoting blades equalize pressure points across the sternum. Suitable for adult patients from 45-90 kg.
Pediatric and Neonatal Retractors
Genesee - Child Curved Sternal Retractor
Multipurpose Retractor for valve repair, valve replacement and on or off-pump coronary artery procedures.
Genesee - Premature Neonate Hinged Retractor
Unique Dynamic “Flip” Feature - Hinged blades rotate 180° from the abdomen to the neck, providing maximum exposure and minimal.
Robotic-Assisted Devices
Genesee - Devices for Robotic-Assisted Procedures
Innovative Tools for Robotic Valve Repair Suture Hooks Specialized tools for suture manipulation Provided with left or right hand hook…
Single-Use Devices
Genesee - Single-Use Devices
Myocardial Temperature Probes: Designed for Ease of Use. Small 22 gauge needle allows for easy insertion. Available in popular Y. S. I. 400 and 2100 series. Needles available in 15 mm, 18 mm, 30 mm and 44 mm. 6 ft. lead wire allows connection to be away from the patient, table and sterile field.
MICS Devices
Dual Design for Multiple Approaches AVATR
Dual Design for Multiple Approaches AVATR is an aortic valve and thoracic retractor for MICS procedures. Left thoracotomy and redo…
