ELGA LabWater
  1. Companies & Suppliers
  2. ELGA LabWater
  3. Downloads
  4. MEDICA R200 Assured Clinical Laboratory ...

MEDICA R200 Assured Clinical Laboratory Reagent Water (CLRW) For Multiple Analyzers Specifications Sheet

MEDICA DIAGNOSTICSThe MEDICA-R 200 features a unique, award winning design incorporating a very high output water purification system, large 350 liter storage reservoir and distribution loop pump. The system is designed to feed large Clinical Laboratory Automation systems, delivering up to 21 l/min of CLSI type 1 pure water directly to multiple Clinical Diagnostic Analyzers across several laboratory areas. By integrating the reservoir and water purification components into one compact system the MEDICA-R 200 is very cost-effective to install and maintain on a loop system.Guaranteed high output – • 200 l/hr pure water productivity, delivering up to 21 l/min to Clinical Diagnostic AnalyzersGuaranteed bacterial specification – onboard technology combined with easy system • sanitization guarantees the CLSI Type 1 bacterial specification of <10 CFU/ml Compact footprint – easy project planning and system installation• Cost effective – use of environmentally friendly regenerated service deionization • cylinders keeps running costs lowEasy operation and control – self monitoring software and remote display units for • convenience and easy managementMEDICA-R 200Water Quality SensorBoostPumpRecirculationPumpTo SDI From SDIReverseOsmosis350 LiterReservoirCVFDrainDrainDrainDrainFeedwaterInletProcess Flow MEDICA-R 200Pre-FilterWater Quality SensorReturnFrom LoopTo DistributionLoop UV Lamp Ultra FilterCompositeVent FilterMEDICA-R 200MEDICA DIAGNOSTICSTreated Water SpecificationsMODEL MEDICA-R 200Make-up rate @15°C 200 l/hrDelivery flow rate – maximum 230V ac, 50Hz – 18 l/min @ 45psi (3bar) ()/115V, 60Hz 21 l/min @ 45psi (3bar)Inorganics (resistivity @25°C) >10 M?-cm1Organics (TOC) - typical <30 ppb1Bacteria - typical <10 CFU/ml2Particles 0.2 µm filterSilica <0.05 mg/l1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance proceduresDimensions and weightsDimensions Height 1820mm (71.7in), Width 730mm (28.75in), Depth 890mm (35in)Supply weight 180 kgsOperational weight 530 kgsInstallation FloorFeedwater RequirementSource Tap water as detailed belowConductivity <1000 µS/cmContaminant Measure Range PretreatmentCalcium Ca ppm as CaCO3 <250 None3>250 Softner or use very low RO recovery3 Free chlorine Cl2ppm <0.1 None0.1 – 0.5 20 inch carbon block>0.5 Cylinder of carbon sized correctly to obtain <0.1 ppmChloramine Cl2 ppm <0.1 None0.1 – 0.5 20 inch high efficiency carbon5 >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppmSilica SiO2 ppm <30 None>30 20 inch cartridge depth filter or use very low RO recovery4Fouling index FI <10 None10 to 20 20 inch cartridge depth filter>20 Back washable media filter with a minimum flow rate of 20 l/minIron/manganese Fe/Mn ppm <0.05 None>0.05 20 inch cartridge depth filter5>0.1 Back-washable Fe filter6Organics TOC ppm C <2 None2 to 3 20 inch carbon block4>3 Cylinder of carbon sized correctly for TOC demand4Temperature 4 - 40°C (Recommended 15 - 25°C)Flowrate (requirement at 15°C) 20 l/minDrain requirements (gravity fall with air gap)45 l/minFeedwater pressure 60psi (4bar) maximum, 30psi (2bar) minimum3 Check LSI, increase frequency of acid cleaning, 4 Increase frequency of alkaline cleaning, 5 Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6 Increase frequency of acid cleaningElectrical RequirementsMains Input 230V ac, 50Hz, 115V, 60HzSystem control voltage (not including pumps and UV)24V dcPower consumption (peak demand)2000VAElectrical protection rating 20 ampsNoise level during recirculation <70dBAELGA LabWaterTel: +44 (0) 1494 887500 Fax: +44 (0) 1494 887505Email: info@elgalabwater.com Website: www.elgalabwater.comELGA® is the global laboratory water brand name of Veolia Water. VWS (UK) Ltd. Registered in England & Wales No. 327847 ©Copyright 2008 ELGA LabWater/VWS (UK) Ltd. All rights reserved. As part of our policy of continual improvement we reserve the right to alter the specifications given in this datasheet.LITR 38760-01
Most popular related searches

Contact supplier

Drop file here or browse