ADITHISRI Radiation Services
Nomex
Hea lt H p H ys i c s nuc l ear m ed i c i n e diagnost ic radiology rad i at i on t H e ra p y Qual i ty controlTrue Precision. PTW.Technical DataMeasuring rangesAir kerma rate R/F 5 µGy/s ... 500 mGy/s, ± 3.5 % (typically ± 1.5 %) Sensitivity Mode 0.1 µGy/s ... 500 mGy/s (typically ± 5 %)Air kerma R/F 50 nGy ... 500 Gy, ± 3.5 % (typically ± 1.5 %)kV R/F (40 ... 150) kV, ± 1.5 % or ± 1 kV (typically ± 0.75 % or ± 0.5 kV)Total filtration (1.5 ... 40) mm Al, ± 10 % or ± 0.5 mm AlHVL R/F (0.95 ... 13.5) mm Al, ± 0.25 mm Al (typically ± 0.1 mm Al)Air kerma rate MAM* 50 µGy/s … 500 mGy/s ± 2.5 %Air kerma MAM* 0.5 µGy ... 500 Gy, ± 2.5 %kV MAM* (23 ... 35) kV, ± 0.5 kVHVL MAM* (0.25 ... 0.75) mm Al, ± 0.01 mm AlDose per pulse 50 nGy ... 500 Gy, ± 3.5 % (typically ± 1.5 %)Pulses 0 ... 99999Frequency 0.2 Hz ... 500 HzIrradiation time 1 ms ... 298 h, ± 1 % or ± 0.5 msPc interface USB V2.0 full speedouter dimensions 115 mm x 50 mm x 9 mmWeight 250 g* Refers to all incl. qualities: Mo/30µmMo, Mo/0.5mmAl, Mo/25µmRh, W/0.7mmAl, W/50µmRh, W/50µmAg, Rh/25µmRh (each with and without compression paddle correction)ordering information[L981815 ] NOMEX multimeterfor measurements in R/F/DENT, CT, MAM. Includes NOMEX multimeter, software on CD, 2 m USB and 5 m long active extension cable, calibration certificate, user manual and a transport case. Requires connection to a PC.options[L991422] Mobile PC[T20016] NOMEX multimeter holder[T20017] NOMEX cassette adapter © D909.139.00/03 Effective 2012/04. Previous specifications are void.Knowing what responsibility meanswww.ptwnomex.com USA | LATin AmericA | chinA | ASiA PAcific | inDiA | UK | frAnce | germAnyTrue to ScaleQual i ty controlconnect ...} Miniaturized multi-parameter measuring device compliant with IEC 61674 for acceptance testing and routine quality control measurements on diagnostic X-ray units (RAD/FLU, DENT, CT, MAM incl. Mo/Mo, Mo/Al, Mo/Rh, W/Al, W/Rh, W/Ag, Rh/Rh)} Connection of the CE marked class IIb certified multimeter to a PC via USB} Single exposure simultaneously captures: dose, dose rate, dose per pulse, pulses, frequency, irradiation time, tube voltage, total filtration, half value layer, together with waveforms for both kV and dose rate} kVpmax, kVpmean and practical peak voltage (PPV) calculation according to the algorithm of IEC 61676} True Precision: Dose accuracy within the RAD/FLU range typically ± 1.5%, within the MAM range ± 2.5% and kV accuracy within the RAD/FLU range typically ± 0.75% or ± 0.5 kVQual i ty control... position ...} Angular independent for positioning within the beam} Ergonomic housing avoids shifting after positioning} Automatic start/stop and auto reset functions} Automatic dose and kV ranging avoids double exposures} Automatic total filtration compensation up to 40 mm Al} Automatic HVL detection for all applications including mammography Qual i ty control... evaluate.} Modifiable parameter displaying (view all parameters at a glance or just selected ones)} Statistic calculations (mean value, standard deviation, coefficient of variation) by simply marking the results of interest} Adjustable timer functions (start or stop delays) and waveform sampling up to 60 seconds} Data and waveform export as XML or CSV file for subsequent data processing in Excel } Software menu available in different languages (German, English, French, Spanish, Portuguese, Italian, Russian, Chinese, Japanese) 2012-04-17T15:38:48+0200 Alexander Kaufhold
Most popular related searches
Stay in the loop!
Select your areas of interest to receive industry updates.