Neurostyle - Model NS-EMG-C-1 - Electromyogram (EMG) System
NS-EMG-C-1 is a digital EMG device. It acquires, stores and review up to 4 channels of EMG data and 2 channels evoked potential (EP) channels. It can perform routine EMG system recording, EP, as well as nerve conductive velocity (NCV) diagnostic examination.
Most popular related searches
nerve conduction
brain surgery
muscle cell
pre-operative
electromyography
electromyogram
surgery
prosthesis
brain mapping
surgery monitoring
EMG System | EMG Device Key Features
- Pre-amplifier operable with up to 4 EMG channels
- High signal quality with USV data transmission, shielding the signal from power line interference
- Consists of 3 standard EMG modules with 4 EP modules
- Easy-to-understand illustations of electrode placements, stimulation positions and standard waveforms
- Easy access to waveform data comparison
- Ability to review and generate report for past cases
System Key Features:
- Pre-amplifier operable with up to 4 EMG channels
- High signal quality with USB data transmission, shielding the signal from power line interference
- Consists of 3 standard EMG modules and 8 NCV modules
- Easy-to-understand illustrations of electrode placements, stimulation positions and standard waveforms
- Easy access to waveform data comparison
- Ability to review and generate report for past cases
- Waveform caching function enables saving of multiple waveforms with the same examination point
- Screen display of individual F-wave, H-wave and overlay
- Display of latency and amplitude values with measurement lines for easy reference
- Current Pulse Output Intensity: Maximum output 100mA; at 0mA ~ 4mA, step difference is 0.01mA. Error = ±10%;
- Pulse Output Frequency: 0.1Hz ~120Hz, error = ±10%;
- Target Pulse Width: 50μS, 100μS, 200μS, 300μS, 500μS, 1000μS; error = ±10%;
- Stimulus Direction: Positive, Negative, and Two-Way.
System Parameters: A. Amplifier Parameters
- Display Sensitivity: 0.05μV/div ~ 20,000μV/div, ±10% error. No precision requirements below 50μV/div.
- Frequency-Amplitude Characteristics: 0.2Hz ~10 kHz, error is +10% ~ -50% between 0.2Hz ~ ≤0.5Hz, and error is +5% ~ -30% between >0.5Hz ~10 kHz.
- Scan Speed: 1ms/div ~ 5000ms/div; error = ±10%;
- High-Pass Filter: 10Hz ~ 20,000Hz; error = +10% ~ -30%;
- Low-Pass Filter: 0.1Hz ~ 5000Hz; error = +10% ~ -30%.
- Common Mode Rejection Ratio: ≥110dB;
- Input Impedance: ≥1000MΩ;
- Noise Voltage:= 0.4μV (RMS);
- Resistance to Polarization Voltage: At ±300 mV DC polarization voltage, bias is ≤5%.
- Current Pulse Output Intensity: Maximum output 100mA; at 0mA ~ 4mA, step difference is 0.01mA. Error = ±10%;
- Pulse Output Frequency: 0.1Hz ~120Hz, error = ±10%;
- Target Pulse Width: 50μs, 100μs, 200μs, 300μs, 500μs, 1000μs; error = ±10%;
- Stimulus Direction: Positive, Negative, and Two-Way.
- Electromyography machines are largely used in clinical settings or hospitals to monitor muscles cells while they are active and at rest.
- The EMG machines are widely used as a research tool for studying kinesiology, motor control disorders.
- The EMG signals can be used to activate or regulate external assistive devices such as orthoses and prosthesis.
- With the advancement of technology the EMG technique and signals are used for neuropsychological mapping during brain surgery, it helps in monitoring the eloquent areas.
- Electromyography is being used in a myriad of evolutionary ways like in engineering applications. The myoelectric signal produces activation magnitude, that magnitude is then used to deduce a target force and motion of a worn mechanical appliance emulsion.
- Display Sensitivity: 0.05μV/div ~ 20,000μV/div, ±10% error. No precision requirements below 50μV/div.
- Frequency-Amplitude Characteristics: 0.2Hz ~10 kHz, error is +10% ~ -50% between 0.2Hz ~ ≤0.5Hz, and error is +5% ~ -30% between >0.5Hz ~10 kHz.
- Scan Speed: 1ms/div ~ 5000ms/div; error = ±10%;
- High-Pass Filter: 10Hz ~ 20,000Hz; error = +10% ~ -30%;
- Low-Pass Filter: 0.1Hz ~ 5000Hz; error = +10% ~ -30%.
- Common Mode Rejection Ratio: ≥110dB;
- Input Impedance: ≥1000MΩ;
- Noise Voltage:= 0.4μV (RMS);
- Resistance to Polarization Voltage: At ±300 mV DC polarization voltage, bias is ≤5%.
A. Normal Mode (Acoustic Stimulation) Parameters
- Stimulation Type: Short Tone, Pure Tone, White Noise.
- Stimulation Frequency: 0.1Hz ~100Hz, error = ±10%;
- Target Signal Probability: 5% ~ 100%, error = ±10%;
- Stimulation Model (for Short Tone and Pure Tone only): Left Ear, Right Ear, Both Ears, Alternate Ears.
- Short Tone Only
- Short Tone Stimulation Phase: Sparse Wave, Dense Wave, Alternating Waves;
- Maximum Short Tone Intensity: approx. 130dB;
- Pure Tone only
- Maximum Pure Sound Intensity: approx. 120dB;
- Pure Tone Sound Frequency: 250Hz ~7kHz, error = ±10%;
- White Noise only
- Maximum White Noise Intensity: approx. 100dB;
- Modulation Type: AM/FM
- Audio Stimulation Intensity: -10dB ~ 130dB HL (Hearing Level), error within ±10%;
- Carrier Frequency: 250Hz ~ 8000 Hz, error within ±10%;
- Modulation Frequency: 20 ~ 200 Hz, error within ±20%;
- Degree of AM: 0 ~ 100%, error within ±30%;
- Degree of FM: 0 ~ 30%, error within ±30%;
- AM/FM Phase Difference: 0 ~ 359 degrees, error within ±30%;
- Checkerboard Image
- Monitor can be set to display full-screen checkerboard image with alternating black-and-white tiles.
- Checkerboard display can be 4X3, 8X6, 16X12, 32X24, or 64X48.
- Half-screen checkerboard display:
- Left-half or right-half of screen: 2X3, 4X6, 8X12, 16X24, or 32X48 pattern,
- Upper or lower half of screen: 4X2, 8X3, 16X6, 32X12, or 64X24 pattern
- Quarter checkerboard display: 2X2, 4X3, 8X6, 16X12, or 32X24 checkerboard pattern.
- Horizontal Bar Grid Image
- Full-screen black-and-white horizontal bar image: 1X3, 1X6, 1X12, 1X24 and 1X48
- Left-half or right-half of screen only: 1X3, 1X6, 1X12, 1X24 and 1X48;
- Top or bottom half of screen only: 1X2, 1X3, 1X6, 1X12 and 1X24,
- Quarter screen display: 1X2, 1X3, 1X6, 1X12 and 1X24.
- Vertical Bar Grid Image
- Full-screen black-and-white alternating vertical bars: 4X1, 8X1, 16X1, 32X1, and 64X1
- Left half or right-half of screen only: 2X1, 4X1, 8X1, 16X1 and 32X1
- Top or bottom half of screen only: 4X1, 8X1, 16X1, 32X1 and 64X1
- Quarter screen display: 2X1, 4X1, 8X1, 16X1, and 32X1.
- Stimulation Frequency: 0.1Hz – 1Hz, error = ± 10 %;
- Target Signal Probability (P300 only): 5% ~ 100%, error = ± 10 %;
- Non-target signal 1 Probability (P300 only): 5% ~ 100%, error = ± 10 %;
- Non-target signal 2 Probability (P300 only): 5% ~ 100%, error = ± 10 %.
- Stimulus Frequency: 0.1Hz – 50Hz, error = ± 10 %;
- Stimulation Modes: Left Eye, Right Eye, Both Eyes, Alternate Eyes.