Microport Orthopedics Inc.

MicroportKinematic Alignment (KA) Technique

SHARE

MicroPort’s Kinematic Alignment (KA) technique, when combined with the Evolution® Medial-Pivot Knee System’s implant design, offers surgeons an innovative solution to problems such as instability, anterior knee pain, and functional limitations. By utilizing traditional mechanical instruments and the “Measure Twice, Cut Once” methodology, surgeons can personalize each total knee replacement case to the individual patient’s joint line and restore their native knee anatomy based on the pre-diseased state. 



Most popular related searches

The Kinematic Alignment technique prioritizes the femoral cuts and compensates for wear on the femur to attain the pre-arthritic joint line. When the Evolution® Medial-Pivot Knee is positioned using Kinematic Alignment, each of the core knee axes are addressed, resulting in ligament isometry and balance without disrupting the patient’s ligaments.

  1. Kinematic Alignment total knees restore function without placing the components at a high risk of failure.3 
  2. By restoring normal anatomic ligament balance, satisfaction rates significantly jump to 92.4%4 
  3. No difference in complication rate between Kinematic and Mechanical Alignment total knees for patients with mild preoperative deformities5 
  4. Kinematic Alignment has shown better outcomes than Mechanical Alignment in standard and combined Knee Society Scores, WOMAC scores, and knee flexion at short-term follow-up6 
  5. Treatment of patients with Kinematic Alignment was shown not to adversely affect the 10-year implant survival, yearly revision rate, and level of function7
Mechanical Alignment: Different Pre-Operative Conditions, Same Approach 

The traditional Mechanical Alignment (MA) technique provides a standardized method for surgeons to insert a knee implant for each patient using a series of non-anatomic cuts that do not account for the patient’s pre-arthritic joint line. Neutral tibial cuts are made independent of the femur, which may result in ligament releases to accommodate the implant in order to achieve a balanced knee. However, this approach precisely fits approximately 2.2% of the patient population.1  

The Kinematic Alignment technique seeks to provide an alternative alignment method that addresses the 20% of knee replacement patients that remain unsatisfied.2 Kinematic Alignment can personalize each total knee replacement to each patient by recreating their pre-diseased joint line and kinematics. Modern day implant designs and materials have enabled more physiological matching through implant motion and alignment. Kinematic Alignment places the implant in the patient’s physiologic position without disrupting the patient’s ligaments.