Ulpatek Air Filter Manufacturing Inc.

UlpatekLaminer Flow Unit for Operating Theatres

SHARE

Operation theatre type Laminar Flow Units are used to supply laminar flow over the operating table and its perimeter. Laminar Flow Units prevent operating zone from microbes, bacteria and other living organisms.

Most popular related searches

Operation theater type Laminar Flow Units are constructed from stainless steel. For filtration H13 / H14 HEPA filters with aluminum frames are used. A laminisator made of special taut silk fabric is used under the laminar flow unite, to achieve laminar flow. Laminisator is made of two parts with a special design that enables pendant lamp connection in the middle of the unit.

In Laminar flow units for operation theater applications, face velocity is taken between 0,2-0,3 m/s. Larger velocities from 0,3 m/s cause draught affect on people under the unite, on the other hand velocities smaller than 0,2 m/s cause deformations in laminar flow.

  • Montage and service friendly with high tech design.
  • DIN 4799 Standart sterility on partial and full capacities.
  • HEPA Filter Box with differential manometer connection probes.
  • Pendant Lamp connection detail.
  • H13 / H14 Filters individual test certificated according to EN 1822 standards, (%99,95 / %99,995 at MPPS efficiencies). Aluminum frame (connection side with gasket, other side with face guard).