TAmiRNA GmbH
- Home
- Companies
- TAmiRNA GmbH
- Products
- osteomiR - microRNA Biomarkers Kit of ...

osteomiR - microRNA Biomarkers Kit of Bone Quality
FromTAmiRNA GmbH
The osteomiR® test enables parallel measurement of 19 carefully selected and validated microRNA biomarkers of bone quality in human serum samples. The osteomiR® software can be used for individual analysis of all 19 microRNA biomarkers, as well as for the calculation of a fracture-risk score. This score is based on multivariate microRNA model.
Most popular related searches
microRNA
human serum
biomarker
muscle research
bone disease
clinical parameter
bone formation
biomarker research
platelet plasma
platelet
- One-stop-shop solution to start microRNA bone and muscle research
- Contains all quality controls required to perform high quality microRNA bone biomarker research
- A single kit allows analysis of 19 osteomiR® microRNA bone quality biomarkers in up to 48 samples
- Cross-species application is possible due the high sequence conservation
- Assess bone quality using the osteomiR® score

- Frozen platelet poor plasma (PPP) aliquots of at least 200 µl
- qPCR instrument (read the manual to find out which instruments are supported)
- High throughput: Analysis of up to 48 serum samples
- Low sample volume: 200 µL human serum (lower volumes can be used but require pre-testing), deep-frozen (-70°C or lower) serum samples can be used (stability for several years has been demonstrated)
- Reduced hands-on time and technical varibility: primer coated 96 or 384 well plates
- 19 osteomiRs and 5 quality controls are measured per sample
- Fast and simple data analysis: the web-based osteomiR® software application enables easy data normalization and quality control
- Standardized analysis of qPCR data
- Import: upload of raw data files from qPCR instrument and automatic Cq-value calling
- Quality Control: inspect amplification curves, melting temperature, spike-in and hemolysis controls
- Normalization: correction of technical variance and optional imputation of missing values
- Export: export normalized Cq-values of all samples and combine automatically with clinical parameters (i.e. age, gender, etc.)
The osteomiR® analysis toolkit and further information will be made available to all registered customers of the osteomiR® kit.
The osteomiR® panel was designed based on a series of research studies, which provide evidence that osteomiRs
- are associated to bone microstructure and histomorphometry
- are regulated in patients with osteoporotic fractures
- are BMD-independent risk factors for osteoporotic fractures
- regulate bone formation and resorption via multiple pathways
- are novel biomarkers for bone diseases