TAmiRNA GmbH
  1. Companies
  2. TAmiRNA GmbH
  3. Products
  4. thrombomiRs - microRNA Biomarkers of ...

thrombomiRsmicroRNA Biomarkers of Platelet Function

SHARE

Circulating platelet microRNAs (thrombomiRs®) are novel biomarkers for intrinsic and on-treatment platelet reactivity. thrombomiRs® are secreted from platelets during their activation and can be detected in plasma and serum. Commonly used platelet function tests e.g. LTA, VerifyNow® or PFA-100®, require fresh blood and agonists. Therefore, they clearly lack standardization and their analytical variability may induce misinterpretations. The thrombomiR® kit enables an in vivo measure of platelet function, independently of the activation pathway.

Most popular related searches
  • One-stop-shop solution to start microRNA platelet function research
  • Contains all quality controls required to perform high quality microRNA biomarker research and publication
  • 1 kit allows to 10 platelet microRNAs in up to 48 samples
  • Cross-species application is possible due the high sequence conservation.
  • Fast and simple data analysis using the thrombomiR analysis toolkit
  • Frozen platelet poor plasma (PPP) aliquots of at least 200 µl
  • qPCR instrument (read the manual to find out which instruments are supported)
  • High throughput: One kit is sufficient for the analysis of 48 platelet poor plasma (PPP) samples
  • Low sample volume: 200 µL PPP are recommended (lower volumes can be used but require pre-testing), (-70°C or lower) PPP samples can be used (stability for several years has been demonstrated)
  • Reduced hands-on time: primer coated 96 or 384 well plates
  • 10 thrombomiR®s and 6 controls/sample are measured per sample
  • Fast and simple data analysis: the web-based thrombomiR® software application enables easy data normalization and quality control

Software application

The thrombomiR® analysis toolkit enables

  • standardized analysis of qPCR data
  • import: upload of raw data files from qPCR instrument and automatic Cq-value calling
  • quality control: inspect amplification curves, melting temperature, spike-in and hemolysis controls
  • normalization: correction of technical variance and optional imputation of missing values
  • export: export normalized Cq-values of all samples and combine automatically with clinical parameters (i.e. age, gender, etc.)

The thrombomiR® analysis toolkit and further information will be made available to all registered customers of the thrombomiR® kit.