Mediaid, Inc.
  1. Companies
  2. Mediaid, Inc.
  3. Products
  4. Mediaid - Model 960 - Pulse Oximeter

MediaidModel 960 - Pulse Oximeter

SHARE

Model 960 Pulse Oximeter with NIBP, Temperature & Printer Option. Applications: Emergency Care, ICU Care, Surgery Room, Hospitals, Physician`s office, Specialty Clinics, Diagnostic Centers.

Most popular related searches
  • Compact Pulse Oximetry System for monitoring Oxygen Saturation (SpO2), Pulse Rate (BPM), Non-Invasive Blood Pressure (NIBP) and Temperature
  • Bright, High resolution LCD screen to display the pleth wave form as well as the SPO2 and Pulse Rate readiungs
  • Seperate bright LED displays for systolic, diastolic and mean Blood Pressure readings.
  • Printer facility for printing reports immediately
  • Accurate BP readings in less than 40 seconds
  • Nurse call facility that alerts the nurse station in case of emergency
  • 24 hour Patient Data storage and trend data
  • Patient data transfer to a computer
  • Software for patient data analysis (Optional)
  • Rechargable battery with internal charger
  • Monitors Adult, Pediatric Parents Weighing above 5 kg

Monitor Functional Specifications

  • Display: High resolution fluroscent backlight 240 X 64 LCD graphical screen for Pleth waveform, Spo2 and BPM readings; 3-digit, bright 7-segment LED displays for NIBP readings
  • Language Options: English
  • Indicator: 7-waveform display; Alarm indicating light; External DC supply indicating light; QRS voice & voice alarming
  • Interface: Measurement parameter cable interface; Power supply socket; Simulated signal output (1V & 5V amplitude optional, tolerance Battery: Chargeable up to 1 hour backup
  • TREND Time: 1–72 hours
  • Recorder: Optional

Non- Inversive Blood Pressure

  • Technique: Oscillometric
  • Measurement Range: Systolic 40-260mmHg; Diastolic 20-200mmHg; Pulse 40-200BPM
  • Accuracy: 3mmHg

Physical Dimensions

  • Dimensions: 202W x 262H x 110D (mm)
  • Weight: 3.4 kg

Enviornmental Conditions

  • Atmospheric Pressure: 760mmHg
  • Humidity: 5 to 95%( non condensing)
  • Operating Temp: 0 - 40C
  • Storage / Transport Temp: Dual-channel
  • No. of Channels: 1 channel, dispalying 1 TEMP value

Electrical Ratings

  • AC Voltage: 100–230V AC, 50 / 60 Hz
  • Battery Type: Rechargable Internal Battery 12V
  • Battery Minimum Run Time: 2 hours in power save mode, no printing and NIBP running at 90min interval; using new fully charged battery

SpO2

  • Measurement & Alarm Range: 0–100%; Resolution: 1%; Precision: ±2% (70–100%), ±3% (60–70%), Not specified (below 60%)
  • PR & Alarm Range: 0–254 bpm; Resolution: 1bpm; Precision: ±1%