TAPI - Model 201 E - Chemiluminescent NH3 Analyzer For Ambient Air Quality Monitoring Brochure

M O D E L 2 0 1 EThe Model 201E NH3 analyzer measuresambient ammonia in selectable ranges from 0-50 ppb to 0-2,000 ppb using thechemiluminescence principle and an API-designed external ammonia converter andsampling system. Ranges are user selectable in1 ppb increments and auto ranging is available.Ammonia is difficult to measure accuratelybecause of a tendency to be absorbed into othermaterials. The “stickiness” of the gas results inslow response times and inaccurateconcentration values. The Model 201E has beendesigned to overcome the problems of ammoniagas analysis through increased flow, minimumsurface area and selected constructionmaterials.In operation, sample gas is passed throughthe M501NH converter, which converts NH3 andother compounds to NO, producing the totaloxides of nitrogen (TNX). In the next cycle thesample is routed through a molybdenumconverter which converts nitrogen oxides (lessNH3) to NO, producing the Tn reading. Thedifference between these readings (TNX – TN =NH3) provides a reading proportional to the NH3concentration. The analyzer software representsthese values in the readout, and independentoutputs are available for each of these values.The Model 201E combines the performanceadvantages of Teledyne API’s Model 200ENO/NOX analyzer with a converter samplingsystem designed specifically for this applicationto produce the most accurate and dependableNH3 measurement system available today.0-50 ppb to 0-2,000 ppb ranges, userselectableMicroprocessor controlledMulti Tasking software allows viewing testvariables while operatingContinuous self checking with warningalarmsExternal converterDesigned to optimize response times– Minimal surface area in contact withsample– low absorption wetted parts– heated sample manifoldAdaptive filtering optimizes response timeTemperature & pressure compensationInternal data logging with 1 min to 24 houraveragesChemiluminescent NH3 Analyzerfor Ambient Air Quality MonitoringFor more information on Teledyne API’s family ofmonitoring instrumentation products, call us or visit ourwebsite at w w w . t e l e d y n e - a p i . c o mM O D E L 2 0 1 ES P E C I F I C A T I O N SModel 201E Chemiluminescent Ambient level NH3Analyzer includes:n Separate analyzer and converter modulesn External pumpn Digital statusn Auto rangingn Ozone scrubbern Permapure dryern Bi-directional RS-232Specify voltage/frequency:nn 100V/50hz nn 100V/60hznn 220V/50hz nn 115V/60hznn 230V/50hz (CE) nn 220V/60hznn 240V/50hzSpecify output voltage:nn 10V nn 5V nn 1V nn 100mVnn 0-20 mA or 4-20 mA non-isolatedAdditional Options:nn Rack Mount (19”) for analyzer and converter,with chassis slidesnn Rack Mount only for analyzer and converternn Isolated 0-20mA or 4-20 mA output(specify channels)nn Multi-drop RS-232 connectionnn External charcoal scrubber for NO2 removal(suggested when analyzer is not connected toexternal vent)Calibration Options:nn Stainless steel valves for selection of customer-supplied zero & span gasnn Model 702 SS Dilution Calibrator for ammoniaAccessories:nn RS-232 Cablenn Expendables Kitnn Spare Parts KitH O W T O O R D E RChemiluminescent NH3 Analyzerfor Ambient Air Quality MonitoringRanges (measureable units): 0-50 to 0-2,000 ppb, operator selectableDual ranges and auto-ranging supportedUnits: ppb, ppm, µg/m3, mg/g3 operatorselectableZero Noise: < 0.5 ppb (RMS)Span Noise: < 0.5% of reading (RMS) above 50 ppbLower Detectable Limit (LDL): 1 ppbZero Drift: 0.5 ppb/24 hours, <1.0 ppb/7 daysSpan Drift: < 1% of reading/24 hours, < 2% of reading/7 daysLag Time: 40 secondsRise and Fall Time: 90% in 120 secondsLinearity: < 1% full scalePrecision: 0.5% of readingSample Flow Rate: 1,000cc/min ±10%Operating Temperature Range: 10 - 30°CDimensions (HxWxD): Analyzer: 7” (178 mm) x 17” (432 mm) x 23.5”(597 mm)Converter: 7” (178 mm) x 17” (432 mm) x 21.5”(597 mm)Weight: Analyzer: 43 lbs (21 kg); Converter 20 lbs (9 kg)External Pump: 16 lbs (7 kg) Power: 100V 50/60 Hz, 115V 60Hz, 220V 50/60Hz,230V 50Hz, 240V 50Hz250 Watts (analyzer), 250 Watts (pump)Analog Outputs: 10V, 5V, 1V, 100 mV, selectableRecorder Offset: ±10%RS-232: Standard, DB-9 connectorStatus (Digital) 12 outputs from optoisolator, included withstandard configurationCurrent Output: 0-20 mA or 4-20 mA isolated outputs (optional)Approvals:NOTE: The values expressed above are in accordance with EPA definitions.All specifications are based on constant conditions.321123Model 201E schematic6565 Nancy Ridge Drive San Diego, CA 92121-2251858-657-9800 Fax 858-657-9816Email api-sales@teledyne.com
Most popular related searches