Logo Medical XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Equipment
  3. canada manitoba
  4. urine serum
Show results for
Products
Services
Applications

Companies


Refine by
Locations
Back to All Locations

  • Canada
  • Manitoba
Brands

  • ezilab
  • advanced instruments
  • sas
  • sun diagnostics assurance
  • accessbio caregene
View all brands
Applications

  • Actionable Molecular Diagnostic System for Physicians
  • Electrolyte Analyzers for Electrolyte Analysis

Urine Serum Equipment & Supplies In Canada Manitoba

45 equipment items found
Available In ManitobaNear Manitoba

REAGEN - Model RND99032 - Avermectin/Ivermectin ELISA Kit

REAGEN - Model RND99032 - Avermectin/Ivermectin ELISA Kit

Manufactured by:Reagen LLC   based inSan Diego, CALIFORNIA (USA)
. · A quick ELISA assay (less than 2 hours regardless of number of samples). Sample Type Detection Limit (ng/g or ppb) Meat/Fish/Shrimp 2.5 Liver 10 Milk 2.5 Urine/Serum 2.5 Water 2.5 Spec:96 T Shelf life:24 months ...
CONTACT SUPPLIER

SAS - Model 087715 - Serum Ultimate Controls Kit

SAS - Model 087715 - Serum Ultimate Controls Kit

Manufactured by:SA Scientific, Ltd.   based inSan Antonio, TEXAS (USA)
Add 4 drops of serum or urine in sample well and read ...
CONTACT SUPPLIER

SAS - Model 087712 - Serum Controls Kit

SAS - Model 087712 - Serum Controls Kit

Manufactured by:SA Scientific, Ltd.   based inSan Antonio, TEXAS (USA)
Add 4 drops of serum or urine in sample well and read ...
CONTACT SUPPLIER

Atlas - Model Amylase - Activity Tests Kit

Atlas - Model Amylase - Activity Tests Kit

Manufactured by:Atlas Medical GmbH   based inBerlin, GERMANY
Amylase activity tests in serum and urine are mainly used in the diagnosis of diseases of the pancreas and in the investigation of pancreatic function. ...
CONTACT SUPPLIER

Model Autolyser ISE - Clinical Analysers

Model Autolyser ISE - Clinical Analysers

Manufactured by:DIALAB® GmbH   based inWr. Neudorf,, AUSTRIA
General Features: Throughput Chemisty only: 250 tests/h, Throughput I.S.E. only: 200 tests/h, Throughput Chemisty + I.S.E: 220 tests/h (based on 20 I.S.E-samples), Test modes: Routine, Batch, Emergencies (STAT), Profiles, Up to 500 tests in memory + unlimited relation tests, Sample: Serum, Urine, Plasma, CSFSample & Calibrator pre-dilution, Cooled reagent ...
CONTACT SUPPLIER

Medica - Model Easy - Electrolyte Analyzers

Medica - Model Easy - Electrolyte Analyzers

Manufactured by:Medica Corporation   based inBedford, MASSACHUSETTS (USA)
Medica’s electrolyte analyzer, EasyElectrolytes™, focuses on the laboratory’s need to deliver sample results economically. The unique electrode design, combined with precise control of calibrator volumes, ensures low-cost operation and faster test ...
CONTACT SUPPLIER

Model EAD400 - Antigen-Down Assay Diluent

Model EAD400 - Antigen-Down Assay Diluent

Manufactured by:Cell Technology   based inDavis, CALIFORNIA (USA)
Bottle Size: 100 mL, 500 mL, 1 L, 10 L. Reduces the effects of the sample matrix and variation among samples. Pre-dilution of the samples is not ...
CONTACT SUPPLIER

AccessBio careGENE - Zika Virus

AccessBio careGENE - Zika Virus

Manufactured by:Access Bio   based inSomerset, NEW JERSEY (USA)
Test Type: Molecular Diagnostics. Package: 96 tests/box. Specimen: RNAs from serum, Urine. Specimen Volume: DNA extract 5 μL. Result Time: 90 min. Storage Condition: below -20°C. Shelf life: 12 ...
CONTACT SUPPLIER

Model Autolyser - Clinical Analysers

Model Autolyser - Clinical Analysers

Manufactured by:DIALAB® GmbH   based inWr. Neudorf,, AUSTRIA
General Features: Throughput up to 250 tests/h, Test modes: Routine, Batch, Emergencies (STAT), Profiles, Up to 500 tests in memory+ unlimited relation tests, Sample: Serum, Urine, Plasma, CSF, Sample & Calibrator pre-dilution, Cooled reagent tray, Non disposable optical glass cuvettes, Solid state photometer with 10 channels 340-700nm, Crash sensor, QC ...
CONTACT SUPPLIER

Sun Diagnostics ASSURANCE - Model INT-06 - Test Kits

Sun Diagnostics ASSURANCE - Model INT-06 - Test Kits

Manufactured by:Sun Diagnostics LLC   based inNew Gloucester,, MAINE (USA)
The metabolites come in individual vials at 20-fold the CLSI recommended test concentrations so that they are easily spiked into serum or urine pools for analysis. ...
CONTACT SUPPLIER

Sun Diagnostics ASSURANCE - Model INT-04 - DRUG Interference Test Kit

Sun Diagnostics ASSURANCE - Model INT-04 - DRUG Interference Test Kit

Manufactured by:Sun Diagnostics LLC   based inNew Gloucester,, MAINE (USA)
Manufacturers and clinical laboratories are doing a reasonably good job assessing endogenous interferents that may alter lab test results. The next big hurdle is the assessment of interference from common drugs. There are literally hundreds of drugs in clinical use, both prescription and over-the-counter, which can vary widely in their blood and urine concentrations and which can introduce errors ...
CONTACT SUPPLIER

Analette II - Model 9008 - Open System Benchtop Chemistry Analyzer

Analette II - Model 9008 - Open System Benchtop Chemistry Analyzer

Manufactured by:Precision Systems Inc.   based inNatick, MASSACHUSETTS (USA)
Lowest Cost of Ownership The 9008 ANALETTE II™ is a Chemistry Analyzer to meet the needs of both general and special analysis ...
CONTACT SUPPLIER

Model Cat. 63610, 63600, 63620 - Small RNA Library Prep Kit for Illumina

Model Cat. 63610, 63600, 63620 - Small RNA Library Prep Kit for Illumina

Manufactured by:Norgen Biotek Corp.   based inThorold, ONTARIO (CANADA)
The library prep workflow could be used for different forms of input including purified total RNA or enriched small RNA, as well as RNA from low content inputs such as plasma, serum and ...
CONTACT SUPPLIER

HTI - Model Lyte Plus - Electrolyte Analyzer

HTI - Model Lyte Plus - Electrolyte Analyzer

Manufactured by:High Technology, Inc. (HTI)   based inNorth Attleboro, MASSACHUSETTS (USA)
System Function: Methodology: Direct Ion Selective Electrode. Sample Type: Serum, Urine . Sample Volume: (Serum, Urine) 65 μl, 100 μl or 140 μl . Throughput: 60 tests/hour . Test Time: Normal (40s), Faster (35s), Fastest (30s). Autosampler: Optional, 21 positions . Reagent Pack: Cal A, Cal B, Waste. ...
CONTACT SUPPLIER

Model Autolyser 100 - Clinical Analysers

Model Autolyser 100 - Clinical Analysers

Manufactured by:DIALAB® GmbH   based inWr. Neudorf,, AUSTRIA
Throughput: Up to 100 tests per hour, Test modes: Routine, Batch, Emergencies (STAT), Sample type: Serum, Plasma, Urine, CSF, Computer: Built-in with touchscreen, Printer: Built-in thermal printer, external printer optional, Sample pre-dilution: Yes, Calibrator pre-dilution: No, Reaction Cuvettes: Disposable, Cuvette Washer: No, Measuring unit: Filter wheel ...
CONTACT SUPPLIER

Biotecnica Instruments - Model BT 1500 - Analyzer

Biotecnica Instruments - Model BT 1500 - Analyzer

Manufactured by:Biotecnica Instruments SpA   based inRoma, ITALY
The Analyzer software is based on Windows OS intuitive and easy to use. It can work 24/24hrs, performing Routine or Urgent (STAT) samples (serum, plasma, urine] in Random ...
CONTACT SUPPLIER

AIVd - Calibrators

AIVd - Calibrators

Manufactured by:Shenzhen AIVD Biotechnology Co. , LTD.   based inCheektowaga, NEW YORK (USA)
Calibration is the foundation of all clinical laboratory testing that insures the accurate reporting of patient results. Calibration is the process that links the analytical signal with the concentration of analyte present in serum, urine or other body ...
CONTACT SUPPLIER

HRJ - Model E900 - Electrolyte Analyzer

HRJ - Model E900 - Electrolyte Analyzer

Manufactured by:HRJ-BIO   based inGaochun District, Nanjing, CHINA
All-in-one reagent pack 7-inch LCD touch screen Intuitive software with friendly Ul One-touch maintenance operation Ready-to-use maintenance reagents. Whole blood, serum, urine (diluted), other Smart calibration and QC program Smart reagent managenment program Auto rerun for abnormal results Smart system diagnosis. Up to 100 samples per hour Minimum sample volume ...
CONTACT SUPPLIER

Optical Q - Immunoassay For the Quantitative Determination of beta-hCG

Optical Q - Immunoassay For the Quantitative Determination of beta-hCG

Manufactured by:Optibio Co., Ltd.   based inCheongju-si, SOUTH KOREA
Human chorionic gonadotropin (hCG) is a glycoprotein hormone for the maternal recognition of pregnancy produced by trophoblast cells that are surrounding a growing embryo, which eventually, forms the placenta after implantation. hCG can be detected in the urine and serum of pregnant women as early as 6 to 15 days after conception. The concentration of hCG ...
CONTACT SUPPLIER

Healgen - Model hCG - One Step Pregnancy Rapid Test Kit

Healgen - Model hCG - One Step Pregnancy Rapid Test Kit

Manufactured by:Healgen Scientific, LLC.   based inHouston, TEXAS (USA)
The hCG One Step Pregnancy Test (Urine) is a rapid chromatographic immunoassay for the qualitative detection of human chorionic gonadotropin (hCG) in urine to aid in the early detection of ...
CONTACT SUPPLIER
  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About Medical XPRT

Medical XPRT is a global marketplace with solutions and suppliers for the medical sector, with product catalogs, articles, industry events, publications & more.

Channels

Solutions

  • Medical XPRT Industry Products
  • Medical XPRT Industry Software
  • Medical XPRT Industry Training
  • Medical XPRT Industry Services
  • Medical XPRT Industry Applications

Latest

  • Medical XPRT Industry News
  • Medical XPRT Industry Events

Publications

  • Medical XPRT Industry Articles
  • Medical XPRT Industry Books
  • Medical XPRT Industry Magazines
  • Medical XPRT Industry Downloads
  • Medical XPRT Industry Videos

Companies

  • Medical XPRT Industry Companies

  • FAQs
  • Company sitemap
  • Category sitemap
Medical XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • Medical XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
XPRT