Manufactured by:CrestOptics S.p.A. based inRome, ITALY
The X-Light V2 by CrestOptics represents a versatile and efficient solution for confocal imaging. Designed for rigorous laboratory applications, the X-Light V2 enables swift and gentle imaging without sacrificing data integrity. Compatible with both upright and inverted microscopes featuring a camera port, it supports diverse research needs. Notably, its ...
Manufactured by:CSR Biotech based inGuangzhou, CHINA
MI-SIM represents a comprehensive super-resolution microscopy solution for live cell imaging, entirely conceived, developed, produced, and marketed by CSR Biotech. This advanced technology was born from the collaborative efforts of an interdisciplinary team at Peking University, renowned for their groundbreaking work in biomedical imaging. As a ...
Manufactured by:Sysmex America, Inc. based inLincolnshire, ILLINOIS (USA)
This bench top unit includes two co-primary hematology analytical modules integrated with a SP-50, 5th generation slidemaker-stainer. The DI-60 cell image analyzer and a floor-standing wagon for system and reagents are optional upgrades. The XN-3100 provides advanced clinical parameters, including NRBCs with every CBC, Immature Granulocytes with every diff, ...
Manufactured by:CrestOptics S.p.A. based inRome, ITALY
CICERO presents an advanced spinning-disk confocal imaging solution designed for high-resolution fluorescence imaging. This compact and adaptable system integrates seamlessly into existing imaging setups, transforming them into reliable confocal systems. CICERO is tailored for use in various scientific disciplines including life sciences, ...
Manufactured by:Fluxion Biosciences Inc based inAlameda, CALIFORNIA (USA)
The BioFlux DCIS integrates the BioFlux controller with a digital microscope, fluorescence, and two cameras. The easy-to-use live cell imaging system been designed with advanced capabilities to simplify demanding cell-based imaging applications with convenience and ...
Manufactured by:Zoetis based inParsippany, NEW JERSEY (USA)
The Vetscan OptiCell provides advanced, automated complete blood count analysis using innovative AI-powered processing and sophisticated cell imaging techniques. The system incorporates Viscoelastic Focusing and classification technology to deliver comprehensive qualitative and quantitative insights rapidly. Complementing this, the Vetscan Imagyst AI Blood Smear ...
Manufactured by:Confocal NL based inAmsterdam, NETHERLANDS
RCM, the advanced re-scan confocal microscopy system by Confocal NL, represents a significant step forward in imaging technology. It incorporates a digital scanner technology that standardizes re-scanning and achieves a speed of 2 frames per second at a resolution of 512x512 pixels. The device is optimized for super-resolution imaging and is equipped with high ...
Manufactured by:ColdQuanta based inBoulder, COLORADO (USA)
ColdQuanta’s high-quality glass cells offer a new level of optical access to in-vacuum experiments. Assembled with an optical contacting process, the cells provide high-quality AR coatings while maintaining very high optical flatness in the cell walls, enabling minimal optical distortion through the cell. The ...
Manufactured by:Isotopia Molecular Imaging based inPetah Tikva, ISRAEL
Localization of Lymph nodes, evaluation of Peritoneovenous (LeVeen) shunt patency, imaging areas of functioning Reticuloendothelial cells, and Gastrointestinal ...
Manufactured by:The Electrospinning Company Ltd. based inDidcot, UNITED KINGDOM
Images taken using a Nikon Eclispe C1 confocal microscope. HepG2 liver cells were grown for 21 days in the Mimetix scaffold. Cells are stained with DAPI and actin; fibres are electrospun together with Rhodamine 6G (a and b). Cancer cells form a 3D network inside the scaffold (c), use the fibres to support themselves (d) and ...
Manufactured by:Curi Bio based inSeattle, WASHINGTON (USA)
The Cytostretcher-LV can be used to perform stretching experiments on an optical ...
Manufactured by:Leadgene Biomedical Inc. based inTainan City, TAIWAN
SARS-CoV-2 virus-like particles B1.351 (Beta) are composed of four structural proteins: Membrane protein (M), Nucleocapsid protein (N), Beta-spike protein (S) and Envelope protein (E). VLPs are produced in mammalian HEK293 cells. ...
Manufactured by:Vala Sciences based inSan Diego, CALIFORNIA (USA)
Lipid droplets are the primary fat storage organelles of fat cells (adipocytes). Lipid droplet size, and number are altered by anti-diabetic and anti-obesity drugs and these effects can be quantified utilizing Vala Science Inc’s Lipid Droplet Kit. The kit can be utilized to quantify lipid droplets in human primary adipocytes, murine 3T3L1 adipocytes, as well as primary or immortalized ...
Manufactured by:Caliber Imaging & Diagnostics, Inc. based inAndover, MASSACHUSETTS (USA)
The VIVASCOPE® 3000 is a handheld confocal imaging system designed to display, capture and store high resolution cellular-level images of skin. This imaging tool allows the operator to freely navigate the device across the skin while delivering stable, repeatable, high quality cellular-resolution images of epithelium of the skin and supporting ...
Manufactured by:Cell Guidance Systems Ltd. based inCambridge, UNITED KINGDOM
LiveLight™ cell culture media and supplements have been reformulated with specific phototoxic components eliminated and replaced. LiveLight™ media and supplements allow prolonged exposure of cells to light whilst maintaining high levels of cell viability and functionality. As shown below, this allows the generation of remarkably improved experimental ...
Manufactured by:Advanced Instruments based inNorwood, MASSACHUSETTS (USA)
Clonal Assurance on Day 0: Cell Metric® set the standard for high-contrast imaging. Cell Metric X raises the bar, delivering faster, easier clonality verification on day 0 to accelerate your path to IND submission—with zero compromise in ...
Manufactured by:VMI Tecnologias based inLagoa Santa, BRAZIL
The DigimamoTM Digital Mammography Unit was developed to offer the very best in diagnostic imaging, through the acquisition of digital images in 2D (conventional) and 3D (three-dimensional evaluation) modes, in addition to making a combination of both. Tomosynthesis provides sharp images of cross-sections of the breast, and with reduced tissue ...
Manufactured by:Virasoft Inc. based inSarıyer, TURKEY
In reporting of breast cancer pathology, mitosis detection and counting of mitotic cells are important factors that affect the tumor grade and the treatment of the patient. Mitotic cell counting requires standardization to a fixed field area. The total number of mitoses per 10 HPF is recorded. Normally, the count is performed manually by pathologists, but automating the process could reduce its ...
Manufactured by:URIT Medical Electronic Co., Ltd. based inGuangxi, CHINA
Al ways Beyond Urinalysis: World Fastest Urinalysis Workflow. 480 T/H for urine dry chemistry analysis. 240 T/H for sediment analysis. Al technology (CNN, deep learning). Modular design & Multiplicate ...
Manufactured by:Bmseed based inMesa, ARIZONA (USA)
Mechanics Module: strain rate up to 1/s, strain up to 20%. Imaging Module: frame rate: 150fps. Electrophysiology Module: 2x60 channels. Physiological stretch of cells to reproduce the environment of cells inside the body; assessment of cell health, function, and maturity using electrophysiological measurements; visualization of ...