Komax - Model VS70L -Vision Test System
The VS70L vision system has a drawer that can hold two medium to large test items with added height for convenience. Correct assembly is checked using a camera and a line laser. The high quality images of the camera can be easily evaluated using the Vision Studio nx test software. The VS70L performs both Vision Test and Height Control Test to ensure the proper installation and insertion depth of components. The system is efficient and easy to use due to individual test sequences and standardized interfaces. Its partitioning feature allows it to be used in environments with varying light irradiation. It is suitable for industries such as automotive, electronics, and medical equipment manufacturing, and can be customized to meet specific requirements. Overall, the Vision System VS70L from Komax Testing is a versatile solution for component verification. Its ease of use, accurate testing results, and adaptability make it a valuable addition to any production line.
VS70L Vision Test
Metric
- Dimensions/height min.: 1930 mm
- Dimensions/height max.: 1970 mm
- Dimensions/width min.: 1200 mm
- Dimensions/width max.: 1420 mm
- Depth max.: 550 mm
- Total weight, without test adapter (modules) approx.: 275 kg
- Voltage (AC), input min.: 100 V
- Voltage (AC), input max.: 240 V
- Frequency, input min.: 50 Hz
- Frequency, input max.: 60 Hz
- Voltage, input, connector: Safety plug (240 V, 16 A, 3-pin)
- power supply 1, voltage (DC): 24 V
- power supply 1, current (DC) max.: 3 A
- Total power, standard (depending on the number of power supply units) max.: 1000 W
- Ambient temperature, operation min.: 10 °C
- Ambient temperature, operation max.: 40 °C
- Ambient temperature, storage min.: -10 °C
- Ambient temperature, storage max.: 60 °C
- Air humidity non-condensing min.: 30 %
- Air humidity non-condensing max.: 75 %
- Emission sound pressure level (according to DIN 45635) max.: 80 dB
- Protection class: IP 10
- Test grid width: 750 mm
- Test grid depth, horizontal: 0° mm
- Test grid area: 0.225 m²
- max. number of test adapters (modules) to be installed for size100x100: 2
- Maximum permissible load on the test grid: 1,1 / 100 g/cm²
- Operating pressure (according to ISO 8573-1: 5/5/4) min.: 5 bar
- Operating pressure (according to ISO 8573-1: 5/5/4) max.: 7 bar
- Compressed-air connection: Kupplungsstecker Rectus G1/4 26AF AW13
- Pneumatic connections min.: 1
- Pneumatic connections max.: 10
- Operating system Windows, based: ja
- Test software CS WIN nx ®, compatible with all systems: ja
- Height control (line laser): Dimensions of test area, length min.: 10 mm
- Height control (line laser): Dimensions of test area, length (depending of the axis) max.: 580 mm
- Height control (line laser): Dimensions of test area, width min.: 5 mm
- Height control (line laser): Dimensions of test area, width max.: 200 mm
- Height control (line laser): Linear unit, axis speed min.: 30 mm/s
- Height control (line laser): Linear unit, axis speed max.: 200 mm/s
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) min.: 1500 ms
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) max.: 3500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) min.: 1500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) max.: 3500 ms
- Vision test (Camera): Dimensions of the test area, length: 300 mm
- Vision test (Camera): Dimensions of the test area, width: 200 mm
- Vision test (Camera): Exposure time: 125 ms
- Vision test (Camera): Possible camera resolution: 2.3, 5.0, 6.2 Mpixel
- Vision test (Camera): Total test time depending on Number of different types (e.g. approx. 8): 50 ms
- Vision test (Camera): Total test time depending on Number of models learned (e.g. approx. 3 per type): 50 ms
- Vision test (Camera): Total test time depending on Number of test positions (e.g. approx. 50): 50 ms
- Vision test (camera): Total test time max.: 300 ms
Imperial
- Dimensions/height min.: 75.98 in
- Dimensions/height max.: 77.55 in
- Dimensions/width min.: 47.24 in
- Dimensions/width max.: 55.9 in
- Depth max.: 21.65 in
- Total weight, without test adapter (modules) approx.: 606.27 lb
- Voltage (AC), input min.: 100 V
- Voltage (AC), input max.: 240 V
- Frequency, input min.: 50 Hz
- Frequency, input max.: 60 Hz
- Voltage, input, connector: Safety plug (240 V, 16 A, 3-pin)
- power supply 1, voltage (DC): 24 V
- power supply 1, current (DC) max.: 3 A
- Total power, standard (depending on the number of power supply units) max.: 1000 W
- Ambient temperature, operation min.: 50 °F
- Ambient temperature, operation max.: 104 °F
- Ambient temperature, storage min.: 14 °F
- Ambient temperature, storage max.: 140 °F
- Air humidity non-condensing min.: 30 %
- Air humidity non-condensing max.: 75 %
- Emission sound pressure level (according to DIN 45635) max.: 80 dB
- Protection class: IP 10
- Test grid width: 29.52 in
- Test grid depth, horizontal: 0° mm
- Test grid area: 2.42 ft²
- max. number of test adapters (modules) to be installed for size100x100: 2
- Maximum permissible load on the test grid: 2,42 / 15,5 lb/in²
- Operating pressure (according to ISO 8573-1: 5/5/4) min.: 72.51 psi
- Operating pressure (according to ISO 8573-1: 5/5/4) max.: 101.52 psi
- Pneumatic connections min.: 1
- Pneumatic connections max.: 10
- Operating system Windows, based: ja
- Test software CS WIN nx ®, compatible with all systems: ja
- Height control (line laser): Dimensions of test area, length min.: 0.39 in
- Height control (line laser): Dimensions of test area, length (depending of the axis) max.: 11.81 in
- Height control (line laser): Dimensions of test area, width min.: 0.19 in
- Height control (line laser): Dimensions of test area, width max.: 7.87 in
- Height control (line laser): Linear unit, axis speed min.: 1.18 in/s
- Height control (line laser): Linear unit, axis speed max.: 7.87 in/s
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) min.: 1500 ms
- Height control (line laser): Total test time, depending on axis speed (e.g., 100) max.: 3500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) min.: 1500 ms
- Height control (line laser): Total test time, depending on Linear unit axis length (e.g., 580) max.: 3500 ms
- Vision test (Camera): Dimensions of the test area, length: 11.81 in
- Vision test (Camera): Dimensions of the test area, width: 7.87 in
- Vision test (Camera): Exposure time: 125 ms
- Vision test (Camera): Possible camera resolution: 2.3, 5.0, 6.2 Mpixel
- Vision test (Camera): Total test time depending on Number of different types (e.g. approx. 8): 50 ms
- Vision test (Camera): Total test time depending on Number of models learned (e.g. approx. 3 per type): 50 ms
- Vision test (Camera): Total test time depending on Number of test positions (e.g. approx. 50): 50 ms
- Vision test (camera): Total test time max.: 300 ms