Refine by
Lumbar Spine Equipment Supplied In Germany
15 equipment items found
Manufactured by:Biedermann Motech GmbH & Co. KG based inVillingen, GERMANY
iMAS 360 is a mini-open, microsurgical TLIF procedure that integrates advanced implants and instrumentation into the surgical workflow. iMAS 360 allows for anterior and posterior fusion, decompression, and instrumentation through a small midline skin incision. iMAS 360 features the MOSS 100 modular pedicle screw system, the TELIX K® steerable titanium interbody system and the DELTA XS pedicle ...
Manufactured by:Aditus Medical GmbH based inBerlin, GERMANY
Ti-6Al-4V ELI (ISO 5832-3) Titanium Alloy raw material; High Elasticity According to Capability of Thoraco-lumbar spine; Low Profile Design; Offers Different Rod Dimensions and Rod Lengths; Different Options for One Level Elasticity or 2 Level ...
Manufactured by:RIWOspine GmbH based inKnittlingen, GERMANY
The PERCULINE joint system is a universal instrument system for percutaneous denervation of the facet and sacroiliac joints using 4 MHz radiofrequency energy in interventional therapeutic pain procedures in the lumbar ...
Manufactured by:CEATEC Medizintechnik GmbH based inWurmlingen, GERMANY
The CCR and CLR retractors are ensuring stable access to the surgical site, providing good visibility and allowing the surgeon the freedom to perform the operation without hand retraction. The CCR retractor system is used for soft tissue retraction at cervical spine. The CLR retractor system can be applied at lumbar spine for medial and ...
Manufactured by:Medisana GmbH based inNeus, GERMANY
For a highly individual and therefore effective massage. With the LCD remote control, you always have all the settings of the armchair and the massage in view or in your hand. Enjoy the deceptively real simulation of six classic massage techniques with one of the six automatic 30-minute programs. Kneading, rolling and tapping massage, pressure point massage, Shiatsu and Swedish massage work on ...
Manufactured by:CEATEC Medizintechnik GmbH based inWurmlingen, GERMANY
Designed for posterior Lumbar and Thoracic spine surgery. The arm design allows the blades to be pre-positioned in the wound prior to attachment. Blades are interchangeable. Multiple blades may be used on each retractor arm. ...
Manufactured by:akrus GmbH & Co KG based inElmshorn, GERMANY
The electrically height adjustable surgeon chair has been designed for procedures in ophthalmology, neuro and skull surgery. Due to the many, versatile adjustments this chair offers comfortable, fatigue free seating and maximum support for the surgeon during the procedure. The pivoting brackets of the arm rests enhance the ease of getting in and out of the chair. Please find more ergonomic and ...
Manufactured by:Hoogland Spine Products GmbH based inFrankfurt am Main, GERMANY
Lumbar spinal decompression is performed with a posterior interlaminar approach. A skin incision of app. 8-9mm is made in the interlaminar window. A conical blunt dilator is introduced in the interlaminar window. A working cannula is introduced over the dilator with the beveled opening of the working cannula directed medially towards the ligamentum flavum. Sequential trimming of the Inferior ...
Manufactured by:Baholzer Endoskopie-Systeme GmbH & Co.KG based inRottweil, GERMANY
Stimulation of the ganglion, failback surgery syndrome, radicular back pain, treatment of chronic & neuropathic pain, radiculopathy, post-herpetic neuralgia. Resaplus is a newly developed catheter for the treatment of chronic pain caused by adhesions in the epidural space or in the ganglia. Due to the structure, an adhesiolysis/neurolysis can be carried out mechanically (Racz principle) as ...
Manufactured by:Hoogland Spine Products GmbH based inFrankfurt am Main, GERMANY
MaxDisc provides treatment for patients who have failed conservative care and are not yet ready for major surgery. It is a minimal access procedure performed on an outpatient basis. Following manual removal of the offending herniation, the MaxDisc ® device is activated to help clean the disc and seal tears in the annulus. As a result, pressure in the disc is reduced, which eases ...
Manufactured by:Vogt Medical Vertrieb GmbH based inKarlsruhe, GERMANY
The pencil point spinal needle has an essential advantage over the quincke point spinal needle. It is safer for the patient and user because this needle has a lateral hole through which the anesthetic is delivered into the spinal space. The needle is therefore to be preferred by beginners and / or inexperienced ...
Manufactured by:medical bees GmbH based inEmmingen Liptingen, GERMANY
Double-hinged retractor for optimal positioning of the spreader. Joints hold in position. Blades are easily connected via snap-lock. Blades 360° rotatable, hook with fixation pin. Simple, easily movable adaptation of blades using two different types of blade connectors. To be used for lumbar and thoracic spinal procedures. Blade connectors with quick coupling or screw are available for the ...
Manufactured by:medical bees GmbH based inEmmingen Liptingen, GERMANY
Lumbar retractor system. Side load for optimal exposure. Blades out of titanium, color-coded, radiolucent. Large variety of valves and ...
Manufactured by:Hoogland Spine Products GmbH based inFrankfurt am Main, GERMANY
Biportal Endoscopic Spine System, BESS, comes out to be one of new trends of treatment of degenerative spine disorders. Literally it has a deeper origin from bilaterally (bilateral approach, one(left) side for scoping and the other(right side) for working) biportal arthroscopic approach by Dr. Schubert and Hoogland1), ...
Manufactured by:RIWOspine GmbH based inKnittlingen, GERMANY
The VERTEBRIS lumbar instrument set is designed for full-endoscopic decompression of the lumbar and thoracic spine. Typical indications include herniated discs, spinal cysts and spinal canal ...