Heating And Cooling Articles & Analysis
14 articles found
Thermal stability generally refers to the ability of collagen to maintain its structure and function during the heating process. Here are some common methods to evaluate the thermal stability of collagen:1. Differential Scanning Calorimetry (DSC)(1) PrincipleDSC is a technique that measures the amount of heat absorbed or released by a sample during ...
“Thermo” means “relating to heat”. “Plastic” can mean either a specific type of material or “the ability to be easily shaped”. Thermoplastics are plastic materials that can be easily shaped with heat. Thermoplastics have become a mainstay of industry and hence modern society. ...
Ventilation –that is—supplying both outside air and re-circulated are at a rate that the majority of occupants of a classroom, gymnasium, office, or sports arena, would find safe and comfortable has been undertaken by such professional groups as ASHRAE (American Society of Heating, Refrigeration and Air Conditioning Engineers) and CDC particularly when it comes to ...
Quick Facts LOCATION: Chicago, Illinois PRIME MOVER: (1) Solar Centaur 40TM Natural Gas Turbine GENERATING CAPACITY: 3,419 kW HEAT RECOVERY EQUIPMENT: (1) Kentube Heat Recovery Steam Generator 50,000/15,000 lbs/hr (fired/unfired) (1) 800 ton Absorption Chiller HEAT RECOVERY APPLICATION: Building Heat, Absorption ...
Quick Facts LOCATION: San Diego, CA MARKET SECTOR: Hospital FACILITY SIZE: 1,030,000 square feet FACILITY PEAK LOAD: 6.8 MW EQUIPMENT: 4.6 MW Solar Turbines Mercury™ 50 gas turbine, absorption chiller FUEL: Natural Gas USE OF THERMAL ENERGY: Space and autoclave heating, absorption chilling and domestic hot water CHP TOTAL EFFICIENCY: 64% ENVIRONMENTAL BENEFITS: Less than ...
Quick Facts LOCATION: Rochester, Minnesota MARKET SECTOR: Healthcare FACILITY SIZE: 3 Million Square Feet, 960 Licensed Beds FACILITY PEAK LOADS: Electric: 12.0 Megawatts Heating: 130,000 lb/hr Steam Cooling: 7,500 Tons TOTAL CHP GENERATING CAPACITY: 7.75 Megawatts HEAT RECOVERY RATE: 24,000 lb/hr of 250 psig Steam HEAT RECOVERY ...
Quick Facts LOCATION: Chicago, Illinois PRIME MOVER: (1) Solar Centaur 40TM Natural Gas Turbine GENERATING CAPACITY: 3,419 kW HEAT RECOVERY EQUIPMENT: (1) Kentube Heat Recovery Steam Generator 50,000/15,000 lbs/hr (fired/unfired) (1) 800 ton Absorption Chiller HEAT RECOVERY APPLICATION: Building Heat, Absorption ...
The highlight moulds means both more machining work and more technical difficulty.It require better machines and skilled workers.In principle, the thinner the highlight shell, the better heat transfer efficiency, and thus the easier to acquire a better weldless plastic part. ...
Traditional injection molding Moulds are made of steels via machining process.Its water lines are made with drilling simple, intersecting,straight holes with lower heat transfer efficiency, uneven temperature on the cavity surface, easily leading warpage on the plastic parts.Highlight molds innovate the mold design and manufacturing process,making use of pressured vapor or fluids ...
The purpose of the paper is to test a Low Exergy heating and cooling system (LowEx system) that enables the creation of healing and comfort conditions for individual user with minimal possible energy use. ...
” However, the more ventilation air is used, the higher the cost of system operation, particularly when the outdoor air needs to be heated or cooled.” Ventilation — “Ventilation is an important factor in the risk of airborne transmission of disease,” the bureau continues. ...
ByE-CO
” But at McAllen’s Rio Grande Regional Hospital, administrators are staying cool with the knowledge that — even in the face of a 33 percent utility rate hike — their electric bill has declined over the past two years. ...
ByE-CO
MCH is also the first hospital to use a closed-loop ground source geothermal system that covers the facility’s entire heating and cooling needs, in place of a traditional central HVAC system. The use of the geothermal heat pumps give MCH much better zoned control while also saving energy. Installing Steril- Aire UVC Emitters in the ...
ByE-CO
Cavitational collapse produces intense local heating (~5000 K), high pressures (~1000 atm), and enormous heating and cooling rates (>10 9 K/sec). ...