blood-cell Downloads
39 downloads found
Premium
1 Introduction 1.1 Intended use The smart Blood DNA Midi prep (m) has been designed for manual isolation of high molecular weight genomic DNA from peripheral blood mononuclear cells (PBMC) derived from fresh or frozen blood stabilized with EDTA, citrate or heparin. ...
Immucor offers the broadest line of traditional Reagent Red Blood Cell products. On average we manufacture over 1750 lots of Reagent Red Blood Cells ...
ByImmucor
They influence the maintenance of many functions in the organism, the synthesis of cells, blood cells, bones and teeth as well as the immune system. The lack of vitamins can result in serious diseases, thus the detection of vitamins is very ...
PuriBlood’s first filter is designed for pRBCs. With 10+ configuration, we believe our solution will meet the expectancy and deliver the best result to the valuable patient. ...
A1c-Cellular is the only HbA1c control on the market with intact red blood cells. A1c-Cellular tests the entire HbA1c procedure, including the lysing of the red blood cell – a step omitted with other controls. This important step ensures the entire system is working properly and providing accurate patient ...
Reliably type red blood cells antigens beyond traditional ABO Blood Grouping reagents. ...
ByImmucor
Deplete human red blood cells (RBCs) from dissociated tissues or residual RBCs from blood derived samples that have previously been subjected to density gradient separation or lysis via Buoyancy Activated Cell Sorting (BACS). RBCs are targeted and removed with an antibody recognizing Glycophorin A (CD235ab). RBC-depleted cells can be used in applications such as flow cytometry, molecular assays, ...
PBMCs– Peripheral Blood mononuclear cells – are a mixture of many subsets of lymphocytes and monocytes. The isolation of PBMCs is fundamental for immunology ...
Hemosep® is different to traditional cell salvage because all blood components are saved, not just red blood cells (RBC). Hemosep® is simple and reproducible way to provide patients with a haemoconcentrated mix of all cell components, including platelets and clotting factors1,2,3,4 , which are lost in traditional cell salvage ...
CCL17, also known as TARC, is constitutively expressed in the thymus and can be upregulated in peripheral blood mononuclear cells. CCL17 is a ligand for the G protein coupled receptors CCR4 and CCR8, and induces chemotactic migration for T lymphocytes, but not monocytes or granulocytes. ...
Diluent is a buffer solution used to dilute blood and prevent cells agglutination. With correct osmotic pressure, ion pressure and the electric conductivity, it can maintain the integrality and original volume of the blood cells. ...
Endothelium is the cover term for the blood-oriented cells in the innermost layer of the vascular wall (intima). Functioning as physiological barrier to tissue, the CD 31- and vWF-positive cells express nitrogen oxide (NO) which plays a role in regulating the tonus of the vascular musculature. Damage to the endothelial cell layer has been assumed to be possibly a causative factor in the ...
The Rarecells® Buffer is used for blood dilution in order to lysate red blood cells without damaging CTC and CTM. The Rarecells® Buffer is provided as a set of three powders ready to be ...
Premium Line range for the preservation and storage at ultra low temperatures, down to -86°C of blood components, blood plasma, human cells and tissues, vaccines and other laboratory samples. The U range is tropicalized, its -80°C freezers can operate up to +43°C of ...
Intensity of light scattered from semiconductor laser beam on the blood cells reflects cell size and intra cellular density. Low angle scatter shows cell size, while the middle and high angle display intracellular information (nucleus and cytoplasmic content). Pulse data thus captured plots 4 2D scattergrams. Independent WBC / Baso channel uses special hemolytic agent that extracts Basophils. ...
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. By virtue of its ...
EKF Diagnostics’ HemataStat II is a microhematocrit centrifuge that provides a quantitative hematocrit reading for up to six blood samples from one 60 second spin. Hematocrit is the volume percentage (%) of red blood cells in blood. The measurement is taken as the amount of red blood cells in relation to the amount of plasma from a spun capillary or venous ...
The Icon-3 is a smart, 3-part differential hematology analyzer that sets new standards in terms of features, functions and style. This iconic laboratory device combines cutting edge technology with a fresh and elegant design. The Icon-3 provides a 22-parameter complete cell blood count report that includes histograms for WBC, RBC and PLT. ...
Rotation Speed: 12 r.p.m. Adjustable rotation angle axis from vertical to horizontal. An elastic shaft drive and clip supports permit the flasks and tubes to be loaded and unloaded while the motor is running. Epoxy coated outer casing. Recommended for extractions of cell cultures, blood tubes and other haematological ...
Interleukin-2 (IL-2) is an interleukin, a type of cytokine signaling molecule in the immune system. It is a 15.5-16 kDa protein that regulates the activities of white blood cells (leukocytes, often lymphocytes) that are responsible for immunity. IL-2 is part of the body's natural response to microbial infection, and in discriminating between foreign ("non-self") and "self". IL-2 mediates its ...