guide-wires Downloads
25 downloads found
Brasseler USA Surgical is pleased to offer two partially threaded guide wires in the DePuy Synthes compatible orthopedic accessories line. These guide wires are used to properly align screws and nails in orthopedic trauma procedures and are designed to fit in OEM procedural ...
Scope of delivery: Seldinger guide wire made of kink resistant Nitinol (5 units, sterile, individually ...
Scope of delivery: Seldinger guide wire made of kink resistant Nitinol with guiding catheter to be used with all TRACOE twist tubes with minimally traumatic ...
Your procedural goals are the same every single day: Simple reliable access in all your ERCP procedures. Whether you are facing a routine ERCP or the most challenging, complex procedures, the Acrobat 2 Wire Guide is the go-to wire that redefines access by providing the optimal combination of tip flexibility and enhanced pushability for everyday, reliable ...
Our Insertion Tool is equipped with a blunt, 21G x 95mm needle. Torquers are available for guide wire sizes up to 0.014” with ABS collar and blue handle. Versions with pink handle and metal collar are available for guide wire size ranges 0.014”-0.025”, 0.025”-0.035” and 0.035”-0.038”. ...
Operable with one hand, this ergonomic torque device is designed to enhance manipulation of the guide wire tip. Simply squeeze and release. ...
State of the art (patented) variable pitch design in BTCP Screw, Designed to achieve an ideal interference screw providing excellent fixation, Variable pitch, blunt thread profile and tapered tip design enables screw to be graft sparing on distal end and tighter fixation on cortical end, Rigid guide wire provides reliable, consistent positioning of the screw at the designated axis and leaves ...
BySironix
Double lumen guiding catheter for simultaneous 2 guide wire placement into the left and right hepatic ...
ENDO-FLEX dilation balloons come with a transparent plastic balloon that offers a uniform diameter with maximum radial force. Both the biliary and the achalasia variants can be easily positioned using a guide wire. X-ray markings supported the exact placement. ...
The guide-wire exists of a NiTi core wire, covered by an extruded PU coating or by a shrunk PTFE tube. The surface exhibits hydrophilic (hydrophobic) attributes. PU-extruded wires are well visible using X-rays over their whole length. PTFE coated wires have 5 cm long points visible under ...
The Merit MAK-NV™ utilizes a small co-axial introducer with dilator and stiffening cannula and guide wire for placement of larger diameter guide wires in non-vascular ...
Carefully read all instructions, warnings and precautions prior to use. Failure to do so may result in complications. The Gallant™ PTCA Dilatation Catheter is a combination of single lumen and dual lumen catheter, comprising an expandable semi-compliant balloon on a rapid exchange (RX) catheter. It is an RX design, and is therefore assembled from a combination of single lumen and dual lumen ...
ByMedinol
The multi-stage dilation balloons have a clear, transparent plastic balloon, which offers a uniform diameter with maximum radial force. Each balloon can gradually reach three different diameters. Both variants can be easily positioned through the endoscope using a guide wire. X-ray markings supported the exact placement. ...
Ace Hydrophilic Guide wires and are used for percutaneous vessel entry to facilitate subsequent introduction(s) of an intravascular device. This device is Supplied sterile in a peel-open pouch. Intended for single use ...
Harland Medical’s FTS7000 Friction Tester is a compact, versatile instrument specifically designed to help you measure the lubricity and durability of coatings for catheters, guide wires, introducers and other medical devices. The FTS7000 measures both surface friction and coating durability by drawing a test sample between two silicone rubber pads clamped at a programmable force, and then ...
Anatomically unfavorable conditions and special issues in the larynx as well as in open tracheal resections, carinal resections or lobectomies, require the use of original TwinStream jet catheters. In order to respond adequately to these special requirements, different jet catheters are available for corresponding indications and associated procedures. Depending on the anatomical specifications ...
Our Introducer Sets consist of an introducer, sheath, dilator, guide wire, straightener and needle. You can choose between femoral versions in sizes from 5 to 8 French, and radial versions in 5 or 6 French, also as hydrophilic versions. Hydrophilic versions are provided with a hydrophilic coated sheath and optionally with a hydrophilic coated guide wire and special catheter needle. ...
The VACS dilatation catheter is a PTV Balloon Catheter with a coaxial shaft construction and a non-compliant balloon which can easily be placed over a guide wire. The low balloon profi le of the VACS® II balloon catheter allows the use of smallest introducers. The VACS III is a particularly high pressure balloon catheter due to a reinforced balloon ...
The PCX Series coating system is a versatile, high-throughput coating platform for applying and curing medical device coatings. It integrates both dip-coating and ultraviolet-curing processes in one compact unit, making it ideal for coating catheters, guide wires, introducers and similar devices. Pre-engineered modules allow you to choose predesigned feature packages and automation levels best ...