Refine by
Implant Specific Articles & Analysis
23 news found
Rejoint has teamed up with the Fraunhofer Project Centre at the University of Twente in Netherlands, and the Fruanhofer Institute for Production Technology (IPT) in Aachen, Germany, in order to develop and validate a titanium tibial tray with an embedded lattice structure for accelerating the osseointegrative process of YourKnee, Rejoint's 3D printed patient-specific ...
The Straight Delivery System is an extension of the PROPEL family of implants. It is specifically engineered for precise, consistent and easy delivery of the PROPEL Mini implant into the ethmoid sinus for maximum tissue apposition. The original curved delivery system will continue to be available with the PROPEL Mini sinus ...
The IlluminOss System is a minimally invasive approach for fracture repair and stabilization through a patient-specific intramedullary implant. The system utilizes a light-curable liquid monomer, contained within an expandable balloon, to create a patient-conforming, rigid implant within the bone canal. ...
The IlluminOss System is a minimally invasive approach for fracture repair and stabilization through a patient-specific intramedullary implant. The system utilizes a light-curable liquid polymer, contained within an expandable balloon, to create a patient-conforming, rigid implant within the bone canal. ...
The Company's Photodynamic Bone Stabilization System is a minimally invasive approach for fracture repair and stabilization through a patient-specific intramedullary implant. The system utilizes a light-curable liquid polymer, contained within an expandable balloon, to create a patient-conforming, rigid implant within the bone canal. ...
When the implant is infused with a monomer, it conforms to the shape of the patient’s intramedullary bone canal. ...
” Using the IlluminOss System, a patient-conforming implant is created to provide strength and stability over the entire length of the implant supporting the weakened bone. ...
Once the balloon is infused with monomer, it conforms to the shape of the patient’s specific bone. The surgeon then activates a light source which delivers visible light to the PET balloon, polymerizing the monomer. The cured, hardened implant provides longitudinal strength and rotational stability over the length of the implant, ...
The IlluminOss System is the world’s only system of its kind which supports the treatment of fractures using patient-specific bone conforming intramedullary implants. IlluminOss’ LightFix Trial is a multi-center study of the IlluminOss System for the treatment of impending and actual pathological fractures in the humerus from metastatic bone disease ...
The Renishaw Healthcare Centre of Excellence is a unique facility that highlights the company's continuing technology advances for the healthcare sector, including patient-specific implants, dentistry and neurosurgery. It contains a mock non-sterile operating theatre and facilities for education, training, workshops and lectures, plus a facility for the ...
The prototype ADEPT software automates a large amount of implant design, which makes it easier to order patient-specific implants. ...
IlluminOss’ minimally invasive procedure incorporates the use of a thin walled PET balloon that is infused with a liquid monomer and inserted into the intramedullary canal of the bone conforming to the shape of the patient’s specific bone. The device forms a hardened implant once the surgeon activates the visible light delivered within the PET ...
This specification covers the materials, dimensional tolerances, constructions, and mechanical properties for standard metallic implantable strands and cables. ...
The location within the simulated vertebral bodies and position of the intervertebral body fusion device with respect to the loading axis will be dependent upon the design and manufacturer's recommendation for implant placement. 1. Scope 1.1 This test method specifies the materials and methods for the axial compressive subsidence testing of non-biologic ...
This specification covers polyoxymethylene (acetal) resin for medical applications. ...
This specification covers the chemical, mechanical, and metallurgical requirements for wrought annealed titanium-6aluminum-4vanadium ELI (extra low interstitial) alloy (R56401) to be used in the manufacture of surgical implants. ...
This specification covers the raw material and final product requirements, and the associated test methods for the selection of porous high density and ultra high molecular weight polyethylenes intended for use in surgical implants. ...
4.1 This guide is intended to provide guidance for the specification and selection of silicone materials for medical device applications. ...
This guide is intended to provide guidance for the specification and selection of fabrication methods for silicones used in medical devices. ...
1. Scope 1.1 This specification covers the material requirements for high-purity, dense aluminum oxide for load-bearing surgical implant applications. 1.2 This specification does not cover finished parts (for example, femoral heads, acetabular inserts, dental ...