Stent Coating Equipment & Supplies
40 equipment items found
Manufactured by:Seleon GmbH based inHeilbronn, GERMANY
Several steps can be completed in one with the device. The protective cap is removed from the stent with the operation of the lever, and at the same time, the drug is applied and dried with sterile ...
Manufactured by:Becton Dickinson and Company (BD) based inFranklin Lakes, NEW JERSEY (USA)
Tepha is developing fully absorbable stents and coatings made from TephaFLEX® material. This could allow for local drug elution while leaving no permanent residual polymer, which might address the issue of late stent thrombosis with current DESs. In addition, Tepha is developing fully absorbable polymer stents containing ...
Manufactured by:Sonaer USA based inMelville, NEW YORK (USA)
SONO-CELL ® Medical Stent Thin Film Coating System with specialized stent arbor. All system components are compatible with the typical solvents and polymers used in stent coating. For example: solvents THF, acetone, DMAC, toluene, chloroform; polymers: urethanes, polycarbonates, silicones, styrenes. Touch ...
Manufactured by:Translumina GmbH based inHechingen, GERMANY
The Translumina Yukon Choice PC drug-eluting stent, coated with Rapamycin (Sirolimus) and the biodegradable component polylactide (PLA), has an excellent history of pre-clinical and long-term clinical ...
Manufactured by:Biosensors International Group, Ltd. based inSingapore, SINGAPORE
Low Late Loss: 9 month in stent late loss 0.13mm6. In Stent late loss in LEADERS = ...
Manufactured by:Biosensors International Group, Ltd. based inSingapore, SINGAPORE
Only the abluminal surface of the stent receives SMS treatment, allowing BA9™ to be contained within the micro-structured surface and delivered with high specificity to the vessel wall of the coronary lesions. The SMS process allows for an increased surface area for a uniform dose of BA9 to be delivered to the target lesion. With no need for polymer or carrier, BA9 and SMS ...
Manufactured by:LimFlow, Inc. based inSan Jose, CALIFORNIA (USA)
Novel electrospun PTFE-covered nitinol Extension Stents are designed to maximize outflow to the foot by keeping valves in the calf open, while blocking smaller veins from taking flow back to the ...
Manufactured by:TaeWoong Medical based inGyeonggi-do, SOUTH KOREA
There are 4 different types for managing tracheobronchial obstruction. ...
Manufactured by:Relisys Medical Devices Limited based inRanga Reddy, INDIA
Highlighting Features: • Complete endothelialization is in 14 days • Lesser strut width hence results in minimal injury • Very low restenosis because of extremely smooth stent surface (mirror finish) • Cobal+C supports complete coverage of struts by neointima • Endothelial monolayer is fully functional – characterized by CD31 / PECAM, thrombomodulin expression • Thin struts ...
Manufactured by:Elixir Medical Corporation based inMilpitas, CALIFORNIA (USA)
The DESyne X2 Novolimus Eluting Coronary Stent System is a low-profile DES with high flexibility and exceptional deliverability. The ultra-thin design of its stent and polymer coating, with no primer coating, results in one of the thinnest coated struts ...
Manufactured by:Bluesail Medical Co., Ltd based inZibo, CHINA
BioFreedom is a polymer- and carrier-free Drug Coated Stent with BA9™ (DCS). The combination of a selectively micro-structured abluminal surface (SMS) and Biolimus A9™ make BioFreedom a unique stent. At least 20% of PCI patients are High Bleeding Risk (HBR)1-9 requiring an individualized approach, BioFreedom provides a more ...
Manufactured by:Bezwada Biomedical LLC based inHillsborough, NEW JERSEY (USA)
Polyoxaester development is based on aliphatic diacids possessing oxygen atoms adjacent to their α-carbons. These diacids are then polymerized in conjunction with a diol by means of a polycondensation reaction. Since organic chemists have used the term ‘oxa’ to designate the replacement of an ethylene group by an oxygen atom, these diacids have been called oxadiacids, and the ...
Manufactured by:MICRO-TECH (Nanjing) Co., Ltd, based inNanjing, CHINA
The highly varied selection of self-expanding stents for the respiratory tracts offers you the right solution for every indication. All in all, different diameters of 14 and 16mm in addition to different lengths of between 40 to 60 mm are available. Spherical ends in addition to the high radial force of the stent ensure a firm hold and minimise migration ...
Manufactured by:pfm Medical Ag based inCologne, GERMANY
The CP Stent is composed of 0.013“ Platinum/Iridium wire that is arranged in a “zig” pattern, laser welded at each joint and over brazed with 24K Gold. It allows expansion from 12 mm to 30 mm. The Covered CP Stent™ is comprised of the Bare CP Stent that is covered with an expandable sleeve of ...
Manufactured by:Biosensors International Group, Ltd. based inSingapore, SINGAPORE
At least 20% of PCI patients are High Bleeding Risk (HBR) where there is a need to avoid prolonged dual antiplatelet therapy (DAPT).1-9 .The BioFreedomTM Drug-Coated Stent (DCS) is significantly safer and significantly more efficacious than a BMS in High Bleeding Risk patients, with a DAPT regime of only one month, the shortest DAPT regime mandated for all ...
Manufactured by:OrbusNeich Medical Company Ltd. based inShatin, N.T., CHINA
Focused Force Angioplasty for Non-Compliant Lesion ...
Manufactured by:Changzhou Rapid Solutions Co.,Ltd based inChangzhou City, CHINA
This machine is used for the catheter and guidewire tipping forming process. It including taper tips, radius tips, soft tips, closed end tips, dilator tips, sheath tips, flaring, neck downs, overlap welds. butt welds, braid to non-braid welds, multilumen applications, balloon tips and welds, guidewire tips and some custom applications. It features a high-quality inductive heating driver board ...
Manufactured by:Allium Ltd based in, ISRAEL
A fully covered flexible stent with a high-radial force and large caliber body, clinically designed to fit the anatomy of the CBD. The Allium self-expandable, large caliber, fully covered and easily removable biliary stents were designed to be used in chronic Common Bile Duct (CBD) obstructions in order to allow excellent intra-luminal flow during its long indwelling period (of up to 3 years). ...
Manufactured by:Concept Medical Inc. based inTampa, FLORIDA (USA)
Conversion of Sirolimus drug into sub-micron sized particles; Nanocarriers created by encapsulation of sub-micron sized Sirolimus drug into highly biocompatible drug Carrier-phospholipid; Encapsulated Sirolimus is coated on stent and parts of balloon; Upon implantation of Abluminus NP at target site, Nanocarriers with Sirolimus drug from stent ...
Manufactured by:Medinol based inTel Aviv, ISRAEL
From crimping through delivery through calcified lesions, expansion and drug elution, drug-eluting stents endure substantial mechanical and chemical stress. Inherently brittle, traditional polymer coatings of drug eluting stents have been shown to develop surface imperfections and deformations, which under stress can crack and even peel away from ...