- Home
- Equipment
- north america
- tissue damage
Refine by
Applications
- Nucleus Replacement System for Degenerative Disc Disease
- Solution for Active Clinical Trials
- Solution for Laser Interstitial Thermal Therapy (LITT) Evidence
- Solution for Clinical Research
- Freeze-Dried Hemostatic for Patients
- Carpal Tunnel for Endoscopic Surgery
- Carpal Tunnel for Syndrome Self Test
- Carpal Tunnel for Thoracic Outlet Syndrome Test (TOS)
- Carpal Tunnel for Depression Test
- Ultrasound Therapy Machine
- Personal Ultrasound Machine for Pain
- Clean air solutions for allergens area
- Clean air solutions for pollution area
- Clean air solutions for bad odor area
- Clean air solutions for bacteria area
- Clean air solutions for virus area
Tissue Damage Equipment Supplied In North America
102 equipment items found
Manufactured by:Adiso Therapeutics based inConcord, MASSACHUSETTS (USA)
ADS051 blocks MRP2 release of HXA3 gradient, while also blocking FPR1 activation of neutrophils within the colonic epithelium. Unlike currently available therapies, this addresses neutrophil-mediated tissue damage, a hallmark of UC pathology. In a healthy volunteer study, ADS051 was safe and well-tolerated and restricted to the gut with limited systemic ...
Manufactured by:Madison Ortho based inSan Juan, PUERTO RICO
Three unique and innovative locking options, in combination with cancellous bone locking screws, increase the stability of the proximal fragment for proximal fractures. Distal oblique locking option to prevent soft tissue damage and increase stability of the distal fragment. Its universal design can be used for right or left ...
Manufactured by:CooperSurgical, Inc. based inTrumbull, CONNECTICUT (USA)
The Sheth Adnexa Clamp incorporates a much thinner and gentler version of the atraumatic Zeppelin jaw to permit increased operative control while minimizing tissue damage. The sleek clamp curvature and 10-inch length provide increased visibility and optimized access to the adnexa during vaginal ...
Manufactured by:Hartwell Medical LLC based inCarlsbad, CALIFORNIA (USA)
The wider specially formed GRANDVIEW blade keeps the tongue out of the way and reduces the need to reposition the blade thus reducing the potential for tissue damage. The unique blade design provides a more anatomically appropriate curve which improves direct ...
Manufactured by:CooperSurgical, Inc. based inTrumbull, CONNECTICUT (USA)
Z-Clamp™ Hysterectomy Clamps feature sturdy, atraumatic jaws that hold tissue firmly with minimal tissue damage. Tip serrations and longitudinal grooves prevent slippage for increased visibility and access. The clamps are offered in both straight and offset handles, including extended-length instruments for deeper pelvic procedures and ...
Manufactured by:Omnis Health LLC. based inNashville, TENNESSEE (USA)
Compatible with the Embrace® lancing device and most commercially available lancing devices, Embrace® lancets feature a tri-beveled and ultra-sharp point tip to reduce any pain and tissue ...
by:Aurora Spine, Inc. based inToronto, ONTARIO (CANADA)
Compatible with all products used in Aurora's Screwless Procedure, the Compass 4D provides optimal access while minimizing tissue damage. Crafted out of titanium, the Compass 4D features three independently moving blades, with an optional fourth blade. Blades are available in various lengths to accommodate patient anatomy and approach. Multiple lights are ...
Manufactured by:Delfi Medical Innovations Inc based inVancouver, BRITISH COLUMBIA (CANADA)
As recommended in current AORN Standards, Recommended Practices and Guidelines, using appropriate limb protection under the cuff can significantly reduce soft tissue damage. In extensive testing using a molding and digitizing technique, Delfi research staff have found that a fitted sleeve that is matched to a specific cuff and that applies a controlled amount of ...
Manufactured by:AROSurgical based inNewport Beach, CALIFORNIA (USA)
The AROSmicro™ Sterile Nylon Suture with Threaded Needle is designed for both plastic and orthopedic surgeries to preform without leaving permanent tissue damage. 12 Per Box. *Comparable to LOOK #911B — with unmatched ...
Manufactured by:IntegriMedical LLC based inPhoenix, ARIZONA (USA)
Traditional needle syringes cause medication to pool and can result in long- term tissue damage. Our Integrity Needle Free Cartridge Injection System dispenses medication uniformly in a consistent, predictable, spray-like ...
Manufactured by:Mirador Biomedical based inSeattle, WASHINGTON (USA)
Compartment syndrome is a condition in which the pressure within a limited space in the body becomes raised, compromising the blood supply and function of the tissues in that part of the body(1). The incidence of compartment syndrome related complications is directly related to the timing of treatment. Early recognition of a compartment syndrome and treatment by fasciotomy is ...
Manufactured by:Peters Surgical based inBoulogne-Billancourt, FRANCE
ENDOWAY single use ø 5 & 12 mm laparoscopic trocars. Made in Polycarbonate without any conductive parts. ENDOWAY trocar has a combination of conical dilating tip (tissue damaged minimized) with a lateral edge (facilitating perforation), associated to a true 5 mm diameter size. Easy introduction of instruments thanks to its conical head shape ...
Manufactured by:Elmed Medical Systems based inYenimahalle, TURKEY
Ballistic shock waves created by the control unit with pressurized medical air are transmitted to the stone with a tissue compatible, stainless steel probe attached to the handpiece unit. Since ballistic energy is generated only with compressed air, no heat is generated. Therefore, it does not cause any tissue damage caused by heat or ...
Manufactured by:Canadian Hospital Specialties Limited (CHS) based inOakville, ONTARIO (CANADA)
The kit offers: Lowered risk for surgical and post-op complications that other procedures may pose (e.g., longer hospital stay, punctured colon, tissue damage, etc.)3. Tools specifically designed for visual and surgical accuracy. Sterilized introducer needle, hemostat, J-guide wire/seeking catheter, scalpel and more. Flexibility as adjunctive or primary procedure ...
Manufactured by:F Care Systems NV based inBerchem, BELGIUM
Several segments in the skin absorb light of different golf lengths. The absorbed light is converted into heat, which leads to tissue damage. The most important absorption happens by melanin (pigment) and hemoglobin ...
Manufactured by:NanoVibronix based inElmsford, NEW YORK (USA)
PainShield by NanoVibronix is a type of ultrasound therapy for pain that delivers fast pain relief for nerve and soft tissue ...
Manufactured by:Convergent Laser Technologies based inAlameda, CALIFORNIA (USA)
Holmium laser system for stone management & soft tissue. Laser Lithotripsy: The Odyssey is the ideal laser system for endourologists. The laser's 2100 nm infrared output can disintegrate stones and ablate tissue with minimal lateral tissue damage. An endourologist can choose from a wide range of fiber sizes to operate ...
Manufactured by:MedChemExpress LLC (MCE) based inMonmouth Junction, NEW JERSEY (USA)
Itepekimab (REGN-3500) is an IgG4 monoclonal antibody against IL-33. Itepekimab reduced airway inflammation and related tissue damage in preliminary clinical studies. Itepekimab has potential effects in asthma, chronic obstructive pulmonary disease (COPD), and atopic dermatitis ...
Manufactured by:Jones Chemicals, Inc based inSarasota, FLORIDA (USA)
Hazardous in case of skin contact (permeator), of eye contact (corrosive). Slightly hazardous in case of skin contact (corrosive). The amount of tissue damage depends on length of contact. Eye contact can result in corneal damage or blindness. Skin contact can produce inflammation and blistering. Inhalation of dust will produce irritation to ...
Manufactured by:Multi Radiance Medical. based inSolon, OHIO (USA)
Narrowly target damaged tissue with Super Pulsed technology designed to jump-start damaged cells. This versatile family of lasers includes the ACTIV PRO LaserShower for treatment of large areas; the ACTIV PRO has more power for faster treatment times and more setting choices; and the versatile ACTIV PRO LaserStim™ which saves time for ...