sampling-container Downloads
15 downloads found
C3 at is a quantitative turbidimetric assay1,2 for the measurement of (C3) in human serum or plasma. Anti-human C3 antibodies form insoluble complexes when mixed with samples containing C3. The scattering light of the immunocomplexes depends of the C3 concentration in the patient sample, and can be quantified by comparison from a calibrator of known C3 ...
The Lp(a)-turbilatex is a quantitative turbidimetric test for the measurement of Lp(a) in human serum or plasma. Latex particles coated with antibodies anti-Lp(a) are agglutinated when mixed with samples containing Lp(a). The agglutination causes an absorbance change, dependent upon the Lp(a) contents of sample that can be quantified by comparison from a calibrator of known Lp(a) concentration. ...
Anti-antithrombin III antibodies when mixed with samples containing antithrombinIII, form insoluble complexes. These complexes cause an absorbance change, dependent upon the antithrombin-III concentration of the patient sample, that can be quantified by comparison from a calibrator of know antithrombin-III concentration. ...
The ASO-latex is a slide agglutination test for the qualitative and semiquantitative detection of anti-streptolysin O (ASO) in human serum. Latex particles coated with streptolysin O (SLO) are agglutinated when mixed with samples containing ...
The RF-latex is a slide agglutination test for the qualitative and semiquantitative detection of RF in human serum. Latex particles coated with human gammaglobulin are agglutinated when mixed with samples containing ...
The Apex Q has an o-ring-free Quartz flow path for high sensitivity and low background for samples that do not contain hydrofluoric acid. The Apex Q gives the fastest rinse-out of any high sensitivity ICP introduction ...
FOB-Turbilatex is a quantitative turbidimetric test for the measurement of human hemoglobin in human feces. Latex particles coated with specific anti- human hemoglobin antibody are agglutinated when mixed with samples containing hemoglobin or hemoglobin/haptoglobin complexes. The agglutination causes an absorbance change, dependent upon the hemoglobin contents of the sample that can be quantified ...
Ventilated cabinets are intended for storing laboratory samples containing formaldehyde. Its extraction system is based on a compact motor that absorbs internal air. One of the sides of the cabinet acts as a collector, generating an air flow directed towards the extraction outlet, after passing through the ...
The Q-Plex Porcine Cytokine High Sensitivity (4-Plex) is a fully quantitative, ELISA-based chemiluminescent assay allowing concurrent measurement of cytokines in serum or plasma samples. A kit contains a 96-well plate, with each well featuring the 4-Plex along with a positive control with all the other reagents necessary to perform the test. Our high quality reagents help ensure the accuracy of ...
DNA•SAL™ is a revolutionary salivary DNA collection kit used for the collection of DNA from saliva. The device abrades cells and saliva in the mouth via a series of serrated edges resulting in the accumulation of a mixture of oral fluids (saliva) and cells that are trapped in an array of voids on the plastic body of the DNA•SAL™ device. The DNA•SAL™ is removed ...
Reach Further.OverviewWhen working with blood samples, researchers face the added challenge of PCR inhibition. Blood samples typically contain multiple inhibitors of PCR – the heme molecule within hemoglobin as well as commonly used anticoagulants such as EDTA and Heparin. ...
This document provides guidance for the detection of emerging SARS-CoV-2 mutants in respiratory tract samples that have previously had SARS-CoV-2 nucleic acid detected. The Applied Biosystems™ TaqMan™ SARS-CoV-2 Mutation Panel assays contain probes to detect reference and mutation sequences. The assays in the TaqMan™ SARS-CoV-2 Mutation Panel are combined with TaqPath™ ...
The Avioq HIV-1 Microelisa System is intended for use as an aid in diagnosis of infection with HIV-1. It is not intended for use in screening blood donors. Developed as a standard two-step indirect microelisa system assay, the Avioq HIV-1 Microelisa System contains coated 96-well microwell plates, color-coded, liquid calibrator and positive control, and a ready-to-use liquid substrate. The ...
Ventia™ is a home-based rapid allergen test for detection of house dust mite allergen which is designed for use by allergic patients and other consumers. The Ventia® kit enables the presence of mite allergen to be detected in a dust extract within ten minutes. All you need to do is take a dust sample from bedding or carpet using the DUSTREAM® collector that is provided with the kit ...
With the Mini X-Flow nebulizer, one can eliminate the need to change ICP sample introduction components for different applications or different sample types.Whether your samples are clean waters, suspensions, sludges or samples with high dissolved solids, the Mini X-Flow nebulizer can handle them all - and with the best ...
