Refine by
Femur Equipment Supplied In Germany
24 equipment items found
Manufactured by:aap Implantate AG based inBerlin, GERMANY
The Distal Lateral Femur Plate is part of the LOQTEQ® plating system. It combines anatomical fit, maximum strength and angular stability with compression capability throughout the length of the plate shaft. Targeting instruments specially designed for the femoral plate permit minimally invasive insertion technique, which aims to reduce soft tissue ...
Manufactured by:aap Implantate AG based inBerlin, GERMANY
Polyaxial positioning of the ø3.5mm screws increases flexibitiy for the surgeon. The LOQTEQ® Distal Lateral Femur Plate 4.5 PP (periprosthetic) is the first plate that can be combined with hinges. ...
Manufactured by:AF Medical GmbH based inSpaichingen, GERMANY
The femur XLOC plate proximal is an anatomically pre-formed plate and intended for fractures of the proximal femur and the trochanter part. The plate combines four types of screws and is designed for the left and right femur in order to cover different femur neck ...
Manufactured by:AF Medical GmbH based inSpaichingen, GERMANY
The proximal head of the femur XLOC plate is anatomically precontoured and the curved shaft is designed to follow the natural shape of the femur ...
Manufactured by:GO German Orthopedic Implants GmbH based inHamburg, GERMANY
Radiographs should include a full A/P (anterior/posterior) view of the pelvis, including the proximal one-half of both femurs and a lateral view of the proximal half of the affected ...
Manufactured by:aap Implantate AG based inBerlin, GERMANY
The correction of axial malalignments in extremities is constantly gaining importance in orthopedic surgery. Particularly in regions close to the knee corrective osteotomies for varus and valgus malalignments (bowleg and knock-knee) change the load on the knee joint and may delay the need for partial or full joint replacement. With the aap osteotomy system, surgeons perform this type of elective ...
Manufactured by:Waldemar Link GmbH & Co. KG based inGermany, GERMANY
The S curvature follows the natural anatomical shape of the femur. Rib profile for high primary stability and structural elasticity, Bone preserving, Minimally invasive implantation, LINK HX ...
Manufactured by:Waldemar Link GmbH & Co. KG based inGermany, GERMANY
The design is adapted to the anatomical shape of the femur. Successfully used for 40 years1. Proven by a wealth of clinical data.1, 5. Minimal occurrence of periprosthetic fractures11. Minimally invasive ...
Manufactured by:medical ECONET GmbH based inOberhausen, GERMANY
Half-Body Fan-Beam System measurement of bone density, world's smallest DEXA fan beam system; Measurement of bone density on femur, LWS and forearm in less than 30 seconds per measuring range. LVA (Lateral Vertebral Assesment) for the detection of lateral vertebral body fractures. Half-body analysis (measurement time 5 minutes). Orthopaedic function for the detection of hip ...
Manufactured by:Euromed Implants GmbH based inStade, GERMANY
The unique femoral cutting guide combines various functionalities in one component. This enables the surgeon to shape the femur fast and accurate with only one guide positioning and fixing. Quadrofit Total Knee system offers mobile and fixed insert options. This enables the surgeon to make the appropriate choice for the ...
Manufactured by:implantcast GmbH based inBuxtehude, GERMANY
The Aida® short stem is designed to provide metaphyseal-only cementless anchorage within the spongiosa of the proximal femur. It is proximally supported at the calcar as well as laterally via the distal tip. Axial and rotational stability also arise from the tapered and trapezoidal cross-sectional geometries. The prosthesis has a circumferential proximal microporous coating, ...
Manufactured by:AF Medical GmbH based inSpaichingen, GERMANY
The XLOC 5.0 instrument set is for the application of the XLOC plates & screws for the lower extremities. It includes instruments specifically designed for the XLOC implants as well as instrumentation for the conventional bone ...
Manufactured by:3B Scientific GmbH based inHamburg, GERMANY
Didactic Human Skull Model on Cerical Spine, 4 part: The Didactic Human Skull Model brings a true value to your classroom or office and is a great tool for teaching the anatomy of the human skull. It was carefully handmade from unbreakable plastic, using 19 distinctive colors to represent the shapes and relationships of the various bone plates of the skull. The plastic skull can be removed from ...
Manufactured by:Waldemar Link GmbH & Co. KG based inGermany, GERMANY
SIMPLE implantation; REPRODUCIBLE results; SUCCESSFUL ...
Manufactured by:Waldemar Link GmbH & Co. KG based inGermany, GERMANY
Two different stem curvatures allow adaptation to the individual patient’s anatomy - for extended support of the implant on the Shenton’s line. The successful ribbed structure provides secure, rotationally stable fixation in the compressed cancellous ...
Manufactured by:Kyoto Kagaku Co., Ltd. based inKyoto, JAPAN
For patient-friendly and accurate positioning learning; Supports scenario based trainings including communication ...
Manufactured by:Waldemar Link GmbH & Co. KG based inGermany, GERMANY
Flexible in a wide range of compatible implants to choose from; Anatomical design, for potential bone and soft tissue preservation; Expandable thanks to compatibility with ...
Manufactured by:Waldemar Link GmbH & Co. KG based inGermany, GERMANY
What really matters - Patient satisfaction: Pain relief; Restoration of function; Joint ...
Manufactured by:Waldemar Link GmbH & Co. KG based inGermany, GERMANY
Anatomically adapted; Minimal bone resection by preserving the femoral neck; Streamlined instrument set for a straightforward ...
Manufactured by:Biovision GmbH based inIlmenau, GERMANY
PolyPIN is a bioresorbable bone pin from polylactide. Metal implants are normally removed in a second operation, once the bone has healed. This not only means additional expense, but is also stressful for the patient! What is more, a second stay in hospital is necessary to remove the metal, involving absence from work and increased risk of complications. The ideal osteosynthesis implant should, ...
