Refine by
Applications
- Prefilled Syringes and Combination Products for Nitrogen Dioxide Gas Sterilization
- Freeze-Dried Hemostatic for Patients
- 3D bioprinting technology for breast disease
- 3D bioprinting technology for lung disease
- 3D bioprinting technology for brain disease
- 3D bioprinting technology for liver disease
- 3D bioprinting technology for skin disease
- 3D bioprinting technology for pancreas disease
- 3D bioprinting technology for prostate disease
Biomedical Research Equipment Supplied In Usa
35 equipment items found
Manufactured by:SiO2 Materials Science based inAuburn, ALASKA (USA)
We provide a common drug contact surface starting at the research and pre-clinical drug development phases, through clinical trials, and on through to commercial ...
Manufactured by:Strathkelvin Instruments Limited based inNorth Lanarkshire, UNITED KINGDOM
SI020 1302 Service Kit (with PP Jackets). These kits are used to service our Strathtox Instrument and our Biomed ...
Manufactured by:Strathkelvin Instruments Limited based inNorth Lanarkshire, UNITED KINGDOM
SI021 - FEP Membranes, 15 in the ...
Manufactured by:Strathkelvin Instruments Limited based inNorth Lanarkshire, UNITED KINGDOM
This is a Clark-type polarographic electrode, with a 22 micron diameter platinum cathode and silver/silver chloride anode, connected by a buffered potassium chloride electrolyte solution. In the normal configuration the cathode is covered with a relatively low permeability polypropylene membrane, in order for the electrode to be used in unstirred solutions or where minimal stirring is required. ...
Manufactured by:Strathkelvin Instruments Limited based inNorth Lanarkshire, UNITED KINGDOM
For continuous in-line oxygen monitoring or for connection to a flow-through respirometer chamber. The acrylic chamber of the flowcell forms a threaded connection to the integral electrode holder. Only the tip of the electrode projects into the water flow. The inlet and outlet tubes are made from stainless steel. To enable the flowcell to be immersed below the surface of the constant temperature ...
Manufactured by:Strathkelvin Instruments Limited based inNorth Lanarkshire, UNITED KINGDOM
The oxygen content of blood can be measured accurately and quickly by the method of Tucker (1967). A small sample of blood is introduced into the chamber containing a solution of ferricyanide. The resulting release of bound oxygen produces an increase in PO2 which is detected by the oxygen electrode. The oxygen content can be calculated from the PO2 change. The base section of the TC 500 is ...
Manufactured by:Strathkelvin Instruments Limited based inNorth Lanarkshire, UNITED KINGDOM
For use with custom designed respiration chambers. The electrode holder is a black acetal cylinder in which the electrode is located so that its tip projects from the end. The holder is used for the insertion of the electrode into the customers’ own respiration chamber. An acrylic collar containing an “O” ring on its inside surface is also provided. This can be cemented over a ...
Manufactured by:SynVivo, Inc. based inHuntsville, ALABAMA (USA)
SynBBB blood-brain barrier model recreates the in vivo microenvironment by replicating a histological slice of brain tissue cells. The model is able to do this by communicating with endothelial cells across the blood-brain barrier (BBB). As a result, shear-induced endothelial cell tight junctions are easily achieved in the SynBBB model using physiological fluid flow. This is something that cannot ...
Manufactured by:SynVivo, Inc. based inHuntsville, ALABAMA (USA)
The SynRAM™ 3D Inflammation Model from SynVivo was developed to study the entire inflammation pathway in a dynamic environment. The SynVivo platform delivers a physiologically realistic model (including flow and shear) and enables real-time tracking of rolling, adhesion, and migration processes. The model recreates a histological slice of co-cultured tissue and/or tumor cells with a lumen ...
Manufactured by:SynVivo, Inc. based inHuntsville, ALABAMA (USA)
SynTumor is a 3D tissue model for real-time visualization and quantitative assessment of cell-cell and cell-drug interactions in a physiologically and morphologically realistic tumor microenvironment. The system enables (a) circulation in the microvasculature, (b) transport across the vessel walls, and (c) delivery to the tumors. Starting with scans of vascular networks incorporated with ...
Manufactured by:CELLINK based inBoston, MASSACHUSETTS (USA)
The go-to 3D bioprinter for cell biologists, tissue engineers and biomedical researchers. Explore the most user-friendly and flexible bioprinter in the world. BIO X is the first 3D bioprinter in the world with Intelligent Printheads (iPH), ensuring your research is always at the forefront. With an ever-growing list of Intelligent Printheads, the ...
Manufactured by:QIAGEN GmbH based inHilden, GERMANY
The EZ1 Advanced XL performs automated nucleic acid purification for a wide range of sample types relevant for molecular diagnostics, human identity testing, forensics, biomedical research, and gene expression ...
Manufactured by:Matexcel based inShirley, NEW YORK (USA)
Tetramethylrhodamine (TRITC) is a bright orange-fluorescent dye with an excitation maximum at 550 nm and an emission maximum at 574 nm.. Product Overview : Matexcel offers a number of labeled biomolecules for biomedical research use.These bioconjugates have been used widely in in-vitro and in-vivo imaging, assay development, diagnostics and drug delivery.. ...
Manufactured by:Noxilizer, Inc based inHanover, MARYLAND (USA)
Noxilizer’s NOX FLEX™ Biodecontamination platform decontaminates a wide range of equipment and devices used in bio-pharmaceutical manufacturing, biomedical research and other industrial applications requiring bioburden reduction or sterilization. Product line includes: the NOX FLEX™ for isolators, the NOX FLEX™ Passport for airlocks and ...
Manufactured by:Oxford Biomedical Research, Inc. based inRochester Hills, MICHIGAN (USA)
This polyclonal antibody to human glutathione S-transferase A1-1 is produced in goat and is provided as an ammonium sulfate ...
Manufactured by:Ardigen based inKraków, POLAND
The Ardigen platform is applying various algorithms, deep neural networks and machine learning techniques for analyzing biomedical images to help scientists and physicians understand and predict the behavior of complex biological systems. We strive to improve accuracy and efficiency of diagnostic and therapeutic procedures by utilizing our biomedical computing competences such as: digital image ...
Manufactured by:Advanced Photonix based inCamarillo, CALIFORNIA (USA)
Advanced Photonix high-quality LED™s and LED-based illumination systems are perfect for many applications. Output, reliability, and wavelength optimization are core elements of our LED illumination technology. From UV to IR, we have the ability to provide highly-efficient illumination for medical, industrial, defense and other applications. Utilizing our unique systems ...
Manufactured by:BIOPAC Systems Inc. based inGoleta, CALIFORNIA (USA)
Low Flow Resistance With High Filtration Efficiency. Use this disposable bacteriological filter with integrated mouthpiece to protect subjects and equipment. AFT36 is intended for use with only SS11LB—35 mm outer diameter fits directly on the outside of the SS11LB airflow ...
Manufactured by:SIGA Technologies, Inc. based inNew York, NEW YORK (USA)
SIGA has developed TPOXX® Injection, an intravenous (IV) formulation of TPOXX® for those patients who are too sick or unable to swallow oral capsules. SIGA completed clinical trials for the IV formulation with funding from the Biomedical Advanced Research and Development Authority (BARDA). In April 2021, SIGA submitted a New Drug Application (NDA) with ...
Manufactured by:Altimmune Inc. based inGaithersburg, MARYLAND (USA)
An intranasal vaccine designed to provide rapid, stable protection against anthrax after a single administration. It is being developed with the support of the U.S. Biomedical Advanced Research and Development Authority, (“BARDA”) for post-exposure prophylaxis against anthrax following exposure to aerosolized B. anthracis ...